Icom IC-T7H [29/36] D battery voltage indication on off

Icom IC-T7H [29/36] D battery voltage indication on off
5
OTHER FUNCTIONS
25
D Power saver duty cycle
This item sets the power saver duty
cycle the ratio of receive circuit ON
to receive circuit OFF while standing
by. The duty cycle can be set to
AUTO, 1:4 or OFF. Setting to AUTO
conserves the most battery power.
D Battery voltage indication ON/OFF
This item sets the battery voltage in-
dication ON or OFF. When set to ON,
the battery voltage is indicated for 2
sec. at power ON (LOW V, 4.516 V
in 0.5 V steps). If the voltage sur-
passes 16 V, OVER V appears and
ashes regardless of this setting.
D DTMF speed
When slow DTMF transmission
speeds are required (such as for
some repeaters) the transceivers rate
of DTMF transmission can be ad-
justed.
D LCD contrast
This item sets function display con-
trast to one of 2 levels. 1 is for low
contrast and 2 is for high contrast.
fastest (100 msec. intervals)
slowest (500 msec. intervals)
low contrast
high contrast
AUTO
Selects 1:4 duty ratio
when receiving no signal
for 5 sec., then 1:8 60
sec. after that.
1:4
Standby : 125 msec.
circuit idle: 500 msec.
OFF
No power save function.
The power saver is deacti-
vated when more than
12 V DC is connected to
the [DC13.5V] jack.