Daikin ATX25J2V1B [23/28] Troubleshooting
![Daikin ATX25J2V1B [23/28] Troubleshooting](/views2/1746307/page23/bg17.png)
21
TROUBLESHOOTING
Troubleshooting
The following cases are not air conditioner troubles but have some reasons. You may just continue using it.
These cases are not troubles.
Case Explanation
Operation does not start soon.
• When ON/OFF button was
pressed soon after operation
was stopped.
• When the mode was reselected.
• This is to protect the air conditioner.
You should wait for about 3 minutes.
Hot air does not flow out soon
after the start of heating
operation.
• The air conditioner is warming up. You should wait for 1 to
4 minutes.
(The system is designed to start discharging air only after it
has reached a certain temperature.)
The heating operation stops
suddenly and a flowing sound
is heard.
• The system is taking away the frost on the outdoor unit.
You should wait for about 3 to 8 minutes.
The outdoor unit emits water
or steam.
In HEAT mode
• The frost on the outdoor unit melts into water or steam
when the air conditioner is in defrost operation.
In COOL or DRY mode
• Moisture in the air condenses into water on the cool
surface of outdoor unit piping and drips.
Mist comes out of the
indoor unit.
This happens when the air in the room is cooled into mist by
the cold airflow during cooling operation.
The indoor unit gives out odour. This happens when smells of the room, furniture, or
cigarettes are absorbed into the unit and discharged with the
airflow.
(If this happens, we recommend you to have the indoor unit
washed by a technician. Consult the service shop where you
bought the air conditioner.)
The outdoor fan rotates while
the air conditioner is not in
operation.
After operation is stopped:
• The outdoor fan continues rotating for another 60
seconds for system protection.
While the air conditioner is not in operation:
• When the outdoor temperature is very high, the outdoor fan
starts rotating for system protection.
The operation stopped
suddenly.
(OPERATION lamp is on.)
For system protection, the air conditioner may stop
operating on a sudden large voltage fluctuation.
It automatically resumes operation in about 3 minutes.
No remote controller signals are
displayed.
The remote controller sensitivity
is low.
The display is low in contrast or
blacked out.
The display runs out of control.
• The batteries are dying and the remote controller is malfunc-
tioning. Replace all the batteries with new, size AAA alkaline
batteries. For details, refer to “To set the batteries” of this
manual. (page 7.)
* If the reset button is provided, press the reset button after the
batteries are replaced.
3PEN291652-2E.book Page 21 Wednesday, February 8, 2017 10:13 AM
Содержание
- Operation manual 1
- Blank page 2
- Contents 3
- Operation 3
- Read before operation 3
- Troubleshooting 3
- Caution 4
- Read before operation 4
- Safety precautions 4
- Warning 4
- Consider nuisance to your neighbours from noises 5
- Electrical work 5
- Installation site 5
- System relocation 5
- Names of parts 6
- Indoor unit 7
- Outdoor unit 7
- Arc433a8 8
- Remote controller 8
- Attention 9
- Preparation before operation 9
- To set the batteries 9
- Attention 10
- Choose a place from where the signals reach the unit 10
- Fix the holder to a wall a pillar or similar location with the screws procured locally 10
- Place the remote controller in the remote controller holder 10
- Preparation before operation 10
- To fix the remote controller holder on the wall 10
- To operate the remote controller 10
- Be careful not to cool heat the room too much keeping the temperature setting at a moderate level helps save energy 11
- Clogged air filters cause inefficient operation and waste energy clean them once in about every two weeks 11
- Cover windows with a blind or a curtain blocking sunlight and air from outdoors increases the cooling heating effect 11
- If you are not going to use the air conditioner for a long period for example in spring or autumn turn the breaker off 11
- Mode fan 11
- Operation 11
- Pen291652 2e book page 9 wednesday february 8 2017 10 13 am 11
- Press clock button 11
- Press timer setting button to set the clock to the present time 11
- The air conditioner always consumes 15 35 watts of electricity even while it is not operating 11
- To set the clock 11
- Turn the breaker on 11
- Use the air conditioner in the following conditions operation outside the humidity or temperature range described in the table may cause a safety device to disable the system 11
- Auto dry cool heat fan operation 12
- Press mode selector button and select an operation mode 12
- Press on off button 12
- Press on off button again 12
- Press temperature adjustment button 12
- To change the temperature setting 12
- To start operation 12
- To stop operation 12
- Press fan setting button 13
- To change the airflow rate setting 13
- Adjusting the airflow direction 14
- Press swing button 14
- To adjust the horizontal blade flap 14
- To adjust the vertical blades louvers 14
- When the flap has reached the desired position press swing button once more 14
- Notes on comfort airflow operation 15
- Notes on flaps and louvers angles 15
- Press comfort airflow button 15
- Press comfort airflow button again 15
- To cancel comfort airflow operation 15
- To start comfort airflow operation 15
- Powerful operation 16
- To cancel powerful operation 16
- To start powerful operation 16
- Econo operation 17
- To cancel econo operation 17
- To start econo operation 17
- Timer operation 18
- To cancel the off timer operation 18
- To use off timer operation 18
- Attention 19
- Press cancel button 19
- Press on timer button 19
- Press on timer button again 19
- Press timer setting button until the time setting reaches the point you like 19
- To cancel on timer operation 19
- To combine on timer and off timer 19
- To use on timer operation 19
- Attach the front panel 20
- Before cleaning be sure to stop the operation and turn the breaker off 20
- Care and cleaning 20
- Caution 20
- Front panel 20
- Indoor unit outdoor unit and remote controller 20
- Open the front panel 20
- Remove the front panel 20
- Wipe them with dry soft cloth 20
- Air filter 21
- Clean or replace each filter 21
- Filters 21
- Open the front panel page 18 21
- Pull out the air filters 21
- Set the air filter and titanium apatite deodorizing filter as they were and close the front panel 21
- Take off the titanium apatite deodorizing filter 21
- Titanium apatite deodorizing filter 21
- Wash the air filters with water or clean them with vacuum cleaner 21
- Before a long idle period 22
- Maintenance 22
- Replacement 22
- Case explanation 23
- These cases are not troubles 23
- Troubleshooting 23
- Call the service shop immediately 24
- Case check 24
- Check again 24
- The power cord is abnormally hot or damaged an abnormal sound is heard during operation the safety breaker a fuse or the earth leakage breaker cuts off the operation frequently a switch or a button often fails to work properly there is a burning smell water leaks from the indoor unit 24
- Turn the breaker off and call the service shop 24
- Warning 24
- Disposal requirements 25
- Important information regarding the refrigerant used 25
- We recommend periodical maintenance 25
- A short beep and two consecutive beeps indicate non corresponding codes 26
- Fault diagnosis 26
- Fault diagnosis by remote controller 26
- In the arc433 series the temperature display sections on the main unit indicate corresponding codes 26
- Press the timer cancel button repeatedly until a continuous beep is produced the code indication changes as shown below and notifies with a long beep 26
- To cancel the code display hold the timer cancel button down for 5 seconds the code display also cancel itself if the button is not pressed for 1 minute 26
- When the timer cancel button is held down for 5 seconds a indication flashes on the temperature display section 26
Похожие устройства
- Daikin ATX25J2V1B Инструкция по монтажу
- Daikin ATX35J2V1B Сервис мануал
- Daikin ATX35J2V1B Инструкция по эксплуатации
- Daikin ATX35J2V1B Инструкция по монтажу
- Daikin ATX20J3V1B Сервис мануал
- Daikin ATX20J3V1B Инструкция по эксплуатации
- Daikin ATX20J3V1B Инструкция по монтажу
- Daikin ATX25J3V1B Сервис мануал
- Daikin ATX25J3V1B Инструкция по монтажу
- Daikin ATX25J3V1B Инструкция по эксплуатации
- Daikin ATX35J3V1B Сервис мануал
- Daikin ATX35J3V1B Инструкция по монтажу
- Daikin ATX35J3V1B Инструкция по эксплуатации
- Daikin FTX20K5V1B Инструкция по эксплуатации
- Daikin FTX20K5V1B Инструкция по монтажу
- Daikin FTX20K2V1B Инструкция по эксплуатации
- Daikin FTX20K2V1B Инструкция по монтажу
- Daikin FTX25K5V1B Инструкция по эксплуатации
- Daikin FTX25K5V1B Инструкция по монтажу
- Daikin FTX25K2V1B Инструкция по эксплуатации