Daikin EHY2KOMB32AA — руководство по установке и настройке системы горячего водоснабжения [52/236]

Daikin EHY2KOMB28AA [52/236] Setup and configuration dhw tank
7 | Application guidelines
Installer reference guide
52
EJHA04AAV3 + EHY2KOMB28+32AA
Daikin Altherma H Hybrid
4P531180-1B – 2020.02
7.4.3 Setup and configuration – DHW tank
For large DHW consumptions, you can heat up the DHW tank several times
during the day.
To heat up the DHW tank to the desired DHW tank temperature, you can use the
following energy sources:
- Thermodynamic cycle of the heatpump
- Gas boiler
For more information about:
- Optimizing the energy consumption for producing domestic hot water, see
"10Configuration"[4124].
- Connecting the electrical wiring of the standalone DHW tank to the gas boiler,
see the installation manual of the DHW tank and the addendum book for
optional equipment.
- Connecting the water piping of the standalone DHW tank to the gas boiler, see
the installation manual of the DHW tank, the addendum book for optional
equipment, and "To connect the electrical wiring to the gas boiler"[4100].
7.4.4 DHW pump for instant hot water
Setup
f
e
a cb
d
a Outdoor unit
b Gas boiler
c Tank
d Cold water
e Shower
f Domestic hot water pump
By connecting a DHW pump, instant hot water can be available at the tap.
The DHW pump and the installation are field supply and the responsibility of the
installer. For the electrical wiring, see "To connect the domestic hot water
pump"[499].
For more information about connecting the recirculation connection, see the
installation manual of the domestic hot water tank.
Configuration
For more information, see "10Configuration"[4124].
You can program a schedule to control the DHW pump via the user interface. For
more information, see the user reference guide.

Содержание

Узнайте, как правильно установить и настроить систему горячего водоснабжения для оптимизации потребления энергии и обеспечения мгновенного горячего водоснабжения.

Скачать