Daikin FHYB60FV1 [24/40] Twin triple double twin multi

Daikin FHYB71FV1 [24/40] Twin triple double twin multi
45 46
DUCT CONNECTION HIGH STATIC PRESSURE TYPE
Cooling capacity
1a/1b
kW
Btu/h
kcal/h
kW
Power consumption
1a/1b
°
CDB
°
CWB
Certified operation range
Model
Name
Indoor unit
Outdoor unit
Dimensions (H
X
W
X
D)
mm
Sound level (H)
2
dB(A)
Refrigerant charge (R-22)
kg
Sound level
2
dB(A)
Dimensions (H
X
W
X
D)
mm
Machine weight
kg
Piping
connections
mm
Liquid (Brazing)
Heat insulation
mm
Gas (Brazing)
mm
Drain Indoor unit
Outdoor unit
kg
Airflow rate (H)
Fan External static pressure
Driving system
m
3
/min
cfm
Pa(mmH
2
O)
Outdoor
unit
mm
Certified operation range
Max. interunit piping length
m
m
Machine weight
Indoor
unit
Colour
Max. installation level difference
Colour
Power supply
kW
Motor output
Compressor
Type
Note :
Models RU08K(U)Y1 and RU10K(U)Y1 are recommended for commercial facilities.
1
Rated cooling capacities are based on the following conditions:
1a
Suction temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal).
1b
Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal).
2
Anechoic chamber conversion value, measured according to JIS parameters and criteria.
During operation these values are somewhat higher owing to ambient conditions.
3
Specification for outdoor unit is for a single unit only.
4
This is the amount of refrigerant required for piping of five meters or less.
Since the unit does not contain refrigerant when shipped from the factory, it must be added at the installation site.
For details, please refer to the installation manual.
----------
Ivory white
Both liquid and gas piping
30
50 (equivalent length 70 m)
14 to 25
Belt drive
98 (10) 147 (15)
Y1: 3 phase, 380–415 V, 50 Hz
21 to 52
Hermetically sealed scroll type
3/4B 1B
200 250 400 500
FD08KY1 FD10KY1
24.3/24.0 29.7/29.2
RU08KY1 RU10KY1
68
2,400
83
2,929
500
X
1,130
X
850 500
X
1,330
X
850
93 104
53
FD15KY1 FD20KY1
RU08KY1
X
2
48.6/47.9 59.3/58.4
RU10KY1
X
2
136
4,800
166
5,859
625
X
1,620
X
850 625
X
1,980
X
850
161 187
58 60
83,000/81,800 101,200/99,600 166,000/163,500 202,400/199,400
20,900/20,600 25,500/25,100 41,800/41,200 51,000/50,200
51
7.5/7.4 9.9/9.8 15.0/14.8 19.8/19.6
177 190
60 61
5.0
(Field charge required for 5 m)
4
6.1
(Field charge required for 5 m)
4
177
X
2 190
X
2
60
3
61
3
5.0
(Field charge required for 5 m)
4
X
2
6.1
(Field charge required for 5 m)
4
X
2
1,220
X
1,280
X
690 1,440
X
1,280
X
690
(1,220
X
1,280
X
690)
X
2 (1,440
X
1,280
X
690)
X
2
7.5 9.0 7.5
X
2
9.0
X
2
o
/
12.7 o
/
15.9 o
/
12.7
X
2 o
/
15.9
X
2
o
/
25.4 o
/
31.8 o
/
25.4
X
2 o
/
31.8
X
2
----------
Simultaneous operation system TWIN & TRIPLE & DOUBLE TWIN MULTI
Model
Name
Indoor unit
Outdoor unit
R125LUY1
71
FHYC35KVE
X
2
R71LUV1
R71LUY1
R100LUV1
R100LUY1
100
FHYC50KVE
X
2
125
FHYC60KVE
X
2
R140LUY1
140
FHYC71KVE
X
2
CEILING MOUNTED CASSETTE TYPE
14 to 25
21 to 46, -15 to 46
4
(Option installed) -5 to 52
494 529 670 670
33/29 33/29 35/30 35/30 39/34 42/36
3.15/3.15 (Y1)
3.17/3.17 (V1)
4.01/4.01 (Y1)
4.06/4.06 (V1)
30
kW
Indoor
unit
3
Dimensions
(H
X
W
X
D)
Colour
Cooling capacity
1a/1b
Btu/h
kcal/h
mm
mm
Sound level (H/L)
2
dB(A)
Refrigerant charge (R-22)
kg
Sound level
2
dB(A)
Dimensions (H
X
W
X
D)
mm
Machine weight
kg
Unit
Both liquid and gas piping
Heat insulation
Decoration
panel
Unit
Decoration panel
Machine weight
kg
kg
Unit
Decoration
panel
Airflow rate (H)
m
3
/min
cfm
Outdoor
unit
Colour
Power consumption
1a/1b
kW
-------------
White
14
230
X
840
X
840
24
15
230
X
840
X
840
24
19
230
X
840
X
840
24
40
X
950
X
950 40
X
950
X
950 40
X
950
X
950
5 5 5
°
CDB
Certified operation range
Certified operation range
°
CWB
26,600/26,200
7.8/7.7
6,700/6,600
36,100/35,700
10.6/10.5
9,100/9,000
44,500/43,600
13.0/12.8
11,200/11,000
770
X
900
X
320 1,170
X
900
X
320 1,170
X
900
X
320
Ivory white
Hermetically sealed scroll type
2.24
2.8
72 (V1), 71 (Y1)
3.00
3.7
87 (V1), 84 (Y1)
3.75
3.7
98
19
988 1,164
28 33
230
X
840
X
840
24
40
X
950
X
950
5
200 250
288
X
840
X
840
28
40
X
950
X
950
5
288
X
840
X
840
28
40
X
950
X
950
5
49,400/48,400
14.5/14.2
12,500/12,200
1,345
X
900
X
320
4.50
4.1
109
5.01/5.01 5.02/5.02 7.7/7.6 9.7/9.7
48 49 49 54
50 (equivalent length 70 m)
Piping
connections
mm
Liquid (Flare)
Max. interunit piping length
mm
Gas
mm
mm
m
m
Drain
Indoor unit
Outdoor unit
Max. installation level difference
R200KUY1
FHYC100KVE
X
2
R250KUY1
FHYC125KVE
X
2
Power supply
VE: 1 Phase, 220–240/220 V, 50/60 Hz V1: 1 Phase, 220–240 V, 50 Hz Y1: 3 Phase, 380–415 V, 50 Hz
Model
Name
Indoor unit
Outdoor unit
R140LUY1
140
FHYC50KVE
X
3
14 to 25
21 to 46, -15 to 46
4
(Option installed)
529
33/29
30
kW
Indoor
unit
3
Dimensions
(H
X
W
X
D)
Colour
Cooling capacity
1a/1b
Btu/h
kcal/h
mm
mm
Sound level (H/L)
2
dB(A)
Refrigerant charge (R-22)
kg
Sound level
2
dB(A)
Dimensions (H
X
W
X
D)
mm
Machine weight
kg
Unit
Both liquid and gas piping
Heat insulation
Decoration
panel
Unit
Decoration panel
Machine weight
kg
kg
Unit
Decoration
panel
Airflow rate (H)
m
3
/min
cfm
Outdoor
unit
Colour
Power consumption
1a/1b
kW
-------------
White
°
CDB
Certified operation range
Certified operation range
°
CWB
Ivory white
Hermetically sealed scroll type
15
670
33/29
19
230
X
840
X
840
24
40
X
950
X
950
5
49,400/48,400
14.5/14.2
12,500/12,200
4.50
1,345
X
900
X
320
4.1 (Charged for 30 m)
109
54
R200KUY1
200
FHYC71KVE
X
3
230
X
840
X
840
24
40
X
950
X
950
5
R200KUY1
200
FHYC50KVE
X
4
230
X
840
X
840
24
40
X
950
X
950
5
R250KUY1
250
FHYC60KVE
X
4
230
X
840
X
840
24
40
X
950
X
950
5
50 (equivalent length 70 m)
Piping
connections
mm
Liquid (Flare)
Max. interunit piping length
mm
Gas
mm
mm
m
m
Drain
Indoor unit
Outdoor unit
Max. installation level difference
35/30
529
33/29
15
670
35/30
19
76,800/75,800
22.5/22.2
19,400/19,100
5.5
1,220
X
1,280
X
690
5.3 (Charged for 5 m)
178
-5 to 52
92,500/90,800
27.1/26.6
23,300/22,900
9.0
1,440
X
1,280
X
690
5.7 (Charged for 5 m)
60 61
202
92,500/90,800
27.1/26.6
23,300/22,900
9.0
1,440
X
1,280
X
690
5.7
202
76,800/75,800
22.5/22.2
19,400/19,100
5.02/5.02 7.7/7.6 9.7/9.77.7/7.6
5.5
1,220
X
1,280
X
690
5.3 (Charged for 5 m)
60
178
76,800/75,800
22.5/22.2
19,400/19,100
5.5
1,220
X
1,280
X
690
5.3
6160
178
Power supply VE: 1 Phase, 220–240/220 V, 50/60 Hz Y1: 3 Phase, 380–415 V, 50 Hz
(Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 30 m) (Charged for 5 m) (Charged for 5 m)
kW
Motor output
Compressor
Type
kW
Motor output
Compressor
Type
Note :
Models R200KU and R250KU are recommended for commercial facilities.
1
Rated cooling capacities are based on the following conditions:
1a
Indoor temp., 27°CDB, 19.5°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal).
1b
Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB. Equiv. refrigeration piping, 5 m (horizontal). (R71LU-R140LU is 7.5 m.)
2
Anechoic chamber conversion value, measured according to JIS parameters and criteria.
During operation these values are somewhat higher owing to ambient conditions.
3
Values shown are for a single unit only.
4
This value is for when year-round cooling kit (option) is installed.
o
/
9.5
o
/
15.9 (Flare)
o
/
9.5
o
/
19.1 (Flare)
o
/
9.5
o
/
19.1 (Flare)
I.Do
/
25
X
O.Do
/
32 I.Do
/
25
X
O.Do
/
32 I.Do
/
25
X
O.Do
/
32 I.Do
/
25
X
O.Do
/
32 I.Do
/
25
X
O.Do
/
32 I.Do
/
25
X
O.Do
/
32
o
/
9.5
o
/
19.1 (Flare)
o
/
26.0 (Hole) o
/
26.0 (Hole) o
/
26.0 (Hole) o
/
26.0 (Hole)
---------
o
/
15.9
o
/
28.6 (Flange)
---------
o
/
12.7
o
/
25.4 (Flange)
---------
o
/
9.5
o
/
19.1 (Flare)
I.Do
/
25
X
O.Do
/
32 I.Do
/
25
X
O.Do
/
32 I.Do
/
25
X
O.Do
/
32I.Do
/
25
X
O.Do
/
32
o
/
26.0 (Hole)
o
/
12.7
o
/
25.4 (Flange)
---------
o
/
15.9
o
/
28.6 (Flange)
---------
o
/
12.7
o
/
25.4 (Flange)

Содержание

Скачать