Daikin FHYB60FV1 [35/40] 1770 24

Daikin FAY100FAVE [35/40] 1770 24
67 68
DUCT CONNECTION HIGH STATIC PRESSURE TYPE
[FDY15KAY1] [FDY20KAY1]
FDY15KAY1
500
A CB D F G H
FDY20KAY1
1042 1620
9XP150=1350
1750 1770 24
E
1710
800
or more
1762 1980
11XP150=1650
2110 2220 542070
Notes:
1
Prepared holes for M4 tapping screw.
Liquid pipe connection (No.1)
Gas pipe connection (No.1)
Liquid pipe connection (No.2)
Gas pipe connection (No.2)
Drain pipe connection
Earth terminal
Hole for power supply
Hole for motor wiring
Hole for wiring from outdoor unit
(No.1)
Hole for wiring from outdoor unit
(No.2)
Hole for remote controller wiring
Control box
The holes for anchor bolts
1
2
3
4
5
6
7
8
9
10
11
12
13
600
100
485
7-
o
/
3.1 holes
*1
4-
o
/
3.1 holes
*1
*1
*1
(Upward and
downward)
(Both sides)
10-
o
/
3.1 holes
10
Air
inlet
Air
outlet
50 or more
50 or more
Supprting plate
(Commercially available)
Supprting plate
(Commercially available)
(Upward and downward)
Service Space
Service Space
55
55
193
349 257
22.5
2XP150=300
A
3XP150=450
544
625
45
38
61
477.5
168200
71.5
72.5 B
BH
C172
D
E
F
G
800 or more
100 or more
100 or more
1045
125
80 80 80
125
80 80 80
20
85035
500 or more
3-
o
/
3.1 holes
10
(Both sides)
Arrow view Arrow view (detail)
763
805 10
35
6
6
14
12
5
5
2
1
4
3
9
10
11
12
6
8
7
DI M E N S I O N S
(Unit: mm)
DUCT CONNECTION HIGH STATIC PRESSURE TYPE
[FD15KY1] [FD20KY1]
FD15KY1
CB D F G H
FD20KY1
1042 1620
9XP.150=1350
1750 1770 24
E
1710
1762 1980
11XP.150=1650
2110 2220 542070
A
10-
o
/
3.1 holes
12-
o
/
3.1 holes
Notes:
1
Prepared holes for M4 tapping screw.
Evaporator air outlet connection
Evaporator air inlet connection
Liquid pipe connection (No.1)
Gas pipe connection (No.1)
Liquid pipe connection (No.2)
Gas pipe connection (No.2)
Drain pipe connection
Earth terminal
Power supply intake
The holes for anchor bolts
1
2
3
4
5
6
7
8
9
10
600
100
7-
o
/
3.1 holes
*1
4-
o
/
3.1 holes
*1
*1
(Upward and
downward)
(Both sides)
3-
o
/
3.1 holes
*1
(Both sides)
A
10
50 or more
Supprting plate
(Commercially available)
(Upward and downward)
Service Space
Service Space
55
55
3XP150=450
2XP150=300
544
625
45
38
257
22.5
349
61
477.5
72.5
6XP.150=900
B
C
D
E
F
G
H
172
800 or more
800 or more
100 or more
50 or more
Supprting plate
(Commercially available)
100 or more
1045
125
80 80 80
125
80 80 80
10
85035
500 or more
763
805 10
10
35
8
9
8
9
10
7
7
1
2
6 5
4 3
OUTDOOR UNIT // R25JV1, R35JV1
100
150
150
50100
300
50 50
50
WALL HEIGHT ON AIR OUTLET SIDE
=LESS THAN 1200
MINIMUM SPACE FOR AIR PASSAGE
A
9.5
12.7
R25JV1
R35JV1
4 –HOLES FOR ANCHOR BOLTS
(
M
8 OR M10
)
NAME PLATE
WIRING INLET
SERVICE PORT
TERMINAL STRIP
WITH EARTH TERMINAL
288
33
70 8
118
115
78
265
20
560
695
12
470
304
74
19
178
420
21
GAS STOP VALVE
(o
/
A CuT)
LIQUID STOP VALVE
(o
/
6.4CuT)
DRAIN OUTLET
(I. D o
/
15.9 HOSE FOR CONNECTION)
HOLES FOR ANCHOR BOLTS
(
M
8 OR M10
)
DRAIN OUTLETS
SERVICE PORT
MINIMUM SPACE FOR AIR PASSAGE
NAME
PLATE
EARTH
TERMINAL
(
M
4
)
POWER INTAKE
GAS STOP VALVE
LIQUID STOP VALVE
237
100
150
150
50100
300
290
306
213
48
95
700
750
+4
0
270
+4
0
540
+4
0
105 58
520
190
170
60
530
100
72
34 27
50 50
50
15
OUTDOOR UNIT // R35GV1, RY35FV1A, R50GV1