Daikin FHYB60FV1 [7/40] Optimal comfort and convenience assured by 3 air discharge modes

Daikin FDBG35AVE [7/40] Optimal comfort and convenience assured by 3 air discharge modes
11 12
Note: Air direc tion is s et to the standard position when the unit is shipped from the factory.
The position c an be changed from the remote controller.
Multi-Flow System Wide air distribution
A newly shaped air discharge opening
increases flow without increasing
wind speed, hence discharged air
reaches farther than before.
Air direction
Desired
situation
Auto-swing
5-levels
air direction
setting
Draft prevention
(In heating mode)
Auto air
direction control
S ettable to 5 different
levels between
10° and 40°
S ettable to 5 different
levels between 10° and 65°
S ettable to 5 different
levels between 30° and 65°
Auto-s wing between
10° and 40°
Auto-s wing between
10° and 65°
Auto-s wing between
30° and 65°
When drafts are unwanted For gentle drafts
(Ceiling is soiled.)
When ceilings must
be kept spotless
Draft prevention setting
Standard setting
Setting to prevent soiling of ceiling
At heating s tartup and thermo
OFF*, air direction is automatical-
ly set to a near horizontal 1 to
prevent direct expos ure to cool
The air direction is s et automatically to the memorised
position of the previous air direc tion. (Initial s etting is 65˚ for
heating and 3 for c ooling.)
At heating s tartup and thermo OFF*, air dis-
charge is automatically s et to 3 to prevent
both direc t exposure to cool air drafts and c on-
1 pattern
4-way flow
4 pattern
3-way flow
3 pattern
2-way flow
" " denotes piping direction. " " denotes sealing
member for air discharge outlet (option) .
Super Cassette
1
2
1
2
(m)
2.7
3
(m)
3.2
4 (m)32101234 (m)
Conventional model
Super Cassette
1
2
1
2
(m)
2.7
3
(m)
3.2
4 (m)32101234 (m)
Conventional model
2.5
m/sec
2.5
m/sec
2.0
m/sec
2.0
m/sec
1.5
m/sec
1.5
m/sec
1.0
m/sec
1.0
m/sec
0.5
m/sec
0.5
m/sec
33˚C
33˚C
30˚C
30˚C
27˚C
25˚C
25˚C
22˚C
22˚C
27˚C
Air discharge temperature comparison
•125K
(In heating)
Air discharge distribution comparison
•125K
BRC7C612W
Signal receiver unit
Wired LCD remote controller Wireless LCD remote controller
A signal receiver must be
added to the indoor unit.
CEILING MOUNTED
CASSETTE TYPE
FH
(
Y
)
C
Quiet, decor-blending form
and easy installation in
new or old buildings.
35
/
30
dB(A)
High Low
Sound level
Wireless remote
controller and
signal receiver unit
are sold as a set.
Note: R emote c ontroller cable not
included. C ables mus t be
procured loc ally.
FHYC35KVE–140KVE
Cooling only FH(Y)C35KVE–140KVE
Heat pump
FHYC71K
Optimal comfort and convenience assured by 3 air discharge modes
Suitable for high ceilings
Switchable fan speed: High/Low
Programme "Dry"
Dehumidification is microprocessor
controlled to prevent abrupt and
uncomfortable changes in air
temperature.
Number of air discharge outlets used
35K–71K
4-way
flow
3-way
flow
2-way
flow
4-way
flow
3-way
flow
2-way
flow
100K–140K
2.7 m
3.0 m
3.5 m
3.0 m
3.3 m
3.5 m
3.5 m
3.8 m
-
3.2 m
3.6 m
4.2 m
3.6 m
4.0 m
4.2 m
4.2 m
4.2 m
-
Note: Operation sound
increas es when
using 2-way
or 3-way
Air direction can be selected
according to installation.
Standard
Ceiling
height
High ceiling
High ceiling
Criteria for ceiling height and number of
air discharge outlets
Accessory required for indoor unit (option)
CEILING MOUNTED CASSETTE TYPE
Note: For 3-way or 2-way flow installation, the
sealing member for air discharge outlet
(option) must be used to clos e off the
unused outlet(s).
60K
35 30
35K
33 29
Unified square panels
All models from the 35K to 140K use
the same size panel. Multiple unit
installations maintain a physical
uniformity that is aesthetically
pleasing and make it easier to plan
ceiling lighting systems and to design
interiors.
Compact body and quiet operation
Draft resistance has been reduced by
incorporating, into a single unit, an
impeller and a diffuser to control air
flow inside the unit. The Diffuser
Turbo Fan is both quiet during
operation and compact.
Note : Anechoic c hamber conversion value,
measured ac cording to J IS parameters and
950
mm
950
mm
Same for
all models
Indoor unit High Low
71K
35 30
50K
33 29
100K
39 34
125K
42 36
140K
44 37
Indoor units use an
aerodynamically designed
Diffuser Turbo Fan
Diffuser
B lade
BRC1C61
Two selectable temperature-sensors
Both indoor unit and wired remote
controller (option) contain temperature-
sensors. Temperature sensing can be
set at the unit or, to further improve
comfort level, closer to the target area
at the wired remote control.
*Temperature-sensor on indoor unit mus t be used
when the air conditioner is controlled from another
room.
**Wireless remote c ontroller does not have a
Guide Line up
P. 3–10
Outdoor units
P. 33–34
Options
P. 57
Outer dimension drawings
P. 60
Remote controllers
P. 35–36
Standard specifications
P. 39, 46, 49, 54
*When the thermostat turns off.
Cooling only
BRC7C613W
Heat pump
Note: Initial settings are for s tandard ceiling
height and 4-way flow. High ceiling settings
1 and 2 are set from the remote
(Installed type)
dB(A)