Daikin CDXS25EAVMT [319/456] Ra indoor unit infrared remote control

Daikin CDXS25EAVMT [319/456] Ra indoor unit infrared remote control
SiEN18-622 Service Check Function
Troubleshooting 307
2. Service Check Function
2.1 RA Indoor Unit Infrared Remote Control
In the ARC433A series remote control, the temperature display sections on the main unit
indicate corresponding codes.
Check Method 1 1. When the timer cancel button is held down for 5 seconds, a “00” indication flashes on the
temperature display section.
2. Press the timer cancel button repeatedly until a continuous beep is produced.
The code indication changes in the sequence shown below, and notifies with a long beep.
<In case of ARC433A46, 47>
Note: 1. A short beep and two consecutive beeps indicate non-corresponding codes.
2. To cancel the code display, hold the timer cancel button down for 5 seconds. The code
display also cancels itself if the button is not pressed for 1 minute.
No. Code No. Code No. Code
1 00 12 C7 23 H0
2 U4 13 H8 24 E1
3 F3 14 J3 25 P4
4 E6 15 A3 26 L3
5 L5 16 A1 27 L4
6 A6 17 C4 28 H6
7 E5 18 C5 29 H7
8 F6 19 H9 30 U2
9 C9 20 J6 31 UH
10 U0 21 UA 32 EA
11 E7 22 A5 33 AH
TEMP
ON/OFF
POWERFUL
MODE FA N
SWING
SILENT
SENSOR
ECONO
MOLD PROOF
TIMER
ON
CANCEL
OFF
(R4794)
<
ARC433A46, A47
>
TIMER CANCEL button
It cancels the timer setting.
No. Code No. Code No. Code
1 00 12 F6 23 A1
2 U4 13 C7 24 E1
3 L5 14 A3 25 UA
4 E6 15 H8 26 UH
5 H6 16 H9 27 P4
6 H0 17 C9 28 L3
7 A6 18 C4 29 L4
8 E7 19 C5 30 H7
9 U0 20 J3 31 U2
10 F3 21 J6 32 EA
11 A5 22 E5 33 AH

Содержание

Скачать