1.3 Control System
1.3.1 Various Control by Liquid Crystal Remote Controller
Note:
1. Though the system on the above figure is structured as a wired remote controller is used, it is possible to replace the wired remote controller with a wireless remote controller to carry out the same or similar control.
2. Impossible to structure with twin wireless remote controllers in case of the control adopting double remote controllers. Be sure to use a wired remote controller for the one of the two controllers.
3. SkyAir series : Possible to extend the wiring length up to 200 m between the wireless remote controller installed independently and the beam receiver (sensor).
(R4925)
Control Method Objective / Use
Unit Name and
Model
Outline of System Function
Standard Number of
Units
Relevant
Page
Number
Control by Remote Controller.
Room Air conditioner
Local operation
of remote
controller
Example of
typical use
ARC433 series
Operational functions
Start/stop (ON/OFF) · Operation change-
over
Temperature setting
Timer setting (the time setting in twenty
four hours)
Air flow rate setting
Air flow direction adjustment (Swing flap)
Intelligent Eye
Inverter powerful operation
Display function
· Operation display
· Operation mode display
·
Temperature setting display
· Timer display
· Air flow rate display
· Intelligent Eye display
· Inverter powerful display
· Abnormal operation display
(at self-diagnose mode)
1 remote controller
controls 1 indoor unit
Wireless
Remote
Controller
Wireless
Remote
Controller
Receiver
The wireless remote controller transmits the signals up to 7m long.