Daikin RRLQ014CAW1 [2/12] Installation manual
![Daikin RRLQ014CAW1 [2/12] Installation manual](/views2/1787391/page2/bg2.png)
1
A~E
a b c d e e
B
e
D
H
B
H
D
H
U
(mm)
a
b
c
d
e
e
B
e
D
A
B
C
D
E
H
B
H
U
H
D
B — ≥200
A, B, C — ≥200 ≥200 ≥200
B, E — ≥200 ≥1000 ≤500
A, B, C, E — ≥300 ≥300 ≥300 ≥1000 ≤500
D — ≥500
D, E — ≥500 ≥1000 ≤500
B, D — ≥200 ≥500
B, D, E H
B
<H
D
H
B
≤½H
U
≥350 ≥750 ≥1000 ≤500
½H
U
<H
B
≤H
U
≥350 ≥1000 ≥1000 ≤500
H
B
>H
U
H
B
>H
D
H
D
≤½H
U
≥200 ≥1000 ≥1000 ≤500
½H
U
<H
D
≤H
U
≥300 ≥1000 ≥1000 ≤500
H
D
>H
U
RRLQ
1
Содержание
- Outdoor unit for air to water heat pump p.1
- Installation manual p.1
- Installation manual p.2
- Pw57793 2a p.3
- Low voltage 2006 95 ec p.3
- Kema nb0344 p.3
- En60335 2 40 p.3
- Electromagnetic compatibility 2004 108 ec p.3
- Dr ing franz grammling managing director 2nd of november 2010 p.3
- Tcf 21f19 06 2010 p.3
- Rrlq011caw1 rrlq014caw1 rrlq016caw1 rrlq011cav3 rrlq014cav3 rrlq016cav3 p.3
- Qua emc02 4565 p.3
- Preparing installation site p.4
- Preparation 4 p.4
- Preparation p.4
- Outdoor unit p.4
- Mounting the outdoor unit p.4
- Installation site requirements of the outdoor unit p.4
- Installation 4 p.4
- Installation p.4
- About this document p.4
- About the documentation 4 p.4
- About the documentation p.4
- To remove the accessories from the outdoor unit p.4
- About the box 4 p.4
- About the box p.4
- To provide the installation structure p.4
- Technical data 10 p.4
- Table of contents p.4
- Starting up the outdoor unit 9 p.4
- To provide drainage p.5
- To prevent the outdoor unit from falling over p.5
- To install the outdoor unit p.5
- To connect the refrigerant piping to the outdoor unit p.5
- Installation p.5
- Connecting the refrigerant piping p.5
- To determine if oil traps are required p.6
- To check for leaks p.6
- Installation p.6
- Checking the refrigerant piping p.6
- B a 4 ø6 mm p.6
- To perform vacuum drying p.7
- To fix the fluorinated greenhouse gases label p.7
- To determine the additional refrigerant amount p.7
- To charge refrigerant p.7
- Installation p.7
- Connecting the electrical wiring p.7
- Charging refrigerant p.7
- To connect the electrical wiring on the outdoor unit p.8
- Specifications of standard wiring components p.8
- Installation p.8
- About electrical compliance p.8
- To reposition the air thermistor on the outdoor unit p.9
- To finish the outdoor unit installation p.9
- Starting up the outdoor unit p.9
- Finishing the outdoor unit installation p.9
- A b c d e p.9
- Wiring diagram outdoor unit p.10
- Wiring diagram p.10
- Technical data p.10
- Service space outdoor unit p.10
- Technical data p.11
- Rotex heating systems sarl p.12
- Rotex heat i ng syst ems gmbh langwiesenstraße 10 d 74363 güglingen fon 49 7135 103 0 fax 49 7135 103 200 p.12
- P385895 1a p.12
- Errors and technical changes reserved 10 2010 p.12
- Daikin airconditioning uk ltd p.12
- Daikin airconditioning spain p.12
- Daikin airconditioning italy s p a p.12
- Daikin airconditioning belgium nv p.12
Похожие устройства
-
Daikin RRLQ016CAW1Руководство по применению для установщика -
Daikin RRLQ016CAW1Инструкция по монтажу -
Daikin RRLQ016CAW1Инструкция по эксплуатации -
Daikin RRLQ014CAW1Руководство по применению для установщика -
Daikin RRLQ014CAW1Инструкция по эксплуатации -
Daikin RRLQ011CAW1Руководство по применению для установщика -
Daikin RRLQ011CAW1Инструкция по монтажу -
Daikin RRLQ011CAW1Инструкция по эксплуатации -
Daikin RRLQ008CAV3Руководство по применению для установщика -
Daikin RRLQ008CAV3Инструкция по монтажу -
Daikin RRLQ008CAV3Инструкция по эксплуатации -
Daikin RRLQ006CAV3Руководство по применению для установщика