Daikin RRLQ014CAW1 — установка и руководство по эксплуатации наружного блока теплового насоса [4/12]
![Daikin RRLQ014CAW1 [4/12] Preparation](/views2/1787391/page4/bg4.png)
Table of Contents
Installation manual
4
RRLQ011~016CA
Outdoor unit for air to water heat pump
4P385895-1A – 2016.03
Table of Contents
1 About the documentation 4
1.1 About this document.................................................................. 4
2 About the box 4
2.1 Outdoor unit............................................................................... 4
2.1.1 To remove the accessories from the outdoor unit....... 4
3 Preparation 4
3.1 Preparing installation site .......................................................... 4
3.1.1 Installation site requirements of the outdoor unit ........ 4
4 Installation 4
4.1 Mounting the outdoor unit.......................................................... 4
4.1.1 To provide the installation structure............................ 4
4.1.2 To install the outdoor unit............................................ 5
4.1.3 To provide drainage.................................................... 5
4.1.4 To prevent the outdoor unit from falling over .............. 5
4.2 Connecting the refrigerant piping .............................................. 5
4.2.1 To connect the refrigerant piping to the outdoor unit .. 5
4.2.2 To determine if oil traps are required.......................... 6
4.3 Checking the refrigerant piping ................................................. 6
4.3.1 To check for leaks....................................................... 6
4.3.2 To perform vacuum drying.......................................... 7
4.4 Charging refrigerant .................................................................. 7
4.4.1 To determine the additional refrigerant amount.......... 7
4.4.2 To charge refrigerant .................................................. 7
4.4.3 To fix the fluorinated greenhouse gases label ............ 7
4.5 Connecting the electrical wiring................................................. 7
4.5.1 About electrical compliance ........................................ 8
4.5.2 Specifications of standard wiring components............ 8
4.5.3 To connect the electrical wiring on the outdoor unit.... 8
4.5.4 To reposition the air thermistor on the outdoor unit .... 9
4.6 Finishing the outdoor unit installation ........................................ 9
4.6.1 To finish the outdoor unit installation .......................... 9
5 Starting up the outdoor unit 9
6 Technical data 10
6.1 Service space: Outdoor unit ...................................................... 10
6.2 Wiring diagram .......................................................................... 10
6.2.1 Wiring diagram: Outdoor unit...................................... 10
1 About the documentation
1.1 About this document
Target audience
Authorised installers
Documentation set
This document is part of a documentation set. The complete set
consists of:
▪ General safety precautions:
▪ Safety instructions that you must read before installing
▪ Format: Paper (in the box of the indoor unit)
▪ Indoor unit installation manual:
▪ Installation instructions
▪ Format: Paper (in the box of the indoor unit)
▪ Outdoor unit installation manual:
▪ Installation instructions
▪ Format: Paper (in the box of the outdoor unit)
▪ Installer reference guide:
▪ Preparation of the installation, technical specifications, good
practices, reference data,…
▪ Format: Digital files on the ROTEX homepage
▪ Addendum book for optional equipment:
▪ Additional info about how to install optional equipment
▪ Format: Paper (in the box of the indoor unit) + Digital files on
the ROTEX homepage
Latest revisions of the supplied documentation may be available on
the regional ROTEX website or via your dealer.
The original documentation is written in English. All other languages
are translations.
2 About the box
2.1 Outdoor unit
2.1.1 To remove the accessories from the
outdoor unit
1×
2
1
a
1×
c
1×
b
2×
d
1×
e
1×
f
1×
g
1×
a Outdoor unit installation manual
b Cable tie
c Fluorinated greenhouse gases label
d Multilingual fluorinated greenhouse gases label
e Screw
f Thermistor fixing plate (spare)
g Thermistor fixture
3 Preparation
3.1 Preparing installation site
3.1.1 Installation site requirements of the
outdoor unit
Mind the spacing guidelines. See the "Technical data" chapter, and
the figures on the inside of the front cover.
The outdoor unit is designed for outdoor installation only, and for
ambient temperatures ranging 10~43°C in cooling mode and –
25~25°C in heating mode.
4 Installation
4.1 Mounting the outdoor unit
4.1.1 To provide the installation structure
Prepare 4 sets of anchor bolts, nuts and washers (field supply) as
follows:
Содержание
- Outdoor unit for air to water heat pump p.1
- Installation manual p.1
- Installation manual p.2
- Pw57793 2a p.3
- Low voltage 2006 95 ec p.3
- Kema nb0344 p.3
- En60335 2 40 p.3
- Electromagnetic compatibility 2004 108 ec p.3
- Dr ing franz grammling managing director 2nd of november 2010 p.3
- Tcf 21f19 06 2010 p.3
- Rrlq011caw1 rrlq014caw1 rrlq016caw1 rrlq011cav3 rrlq014cav3 rrlq016cav3 p.3
- Qua emc02 4565 p.3
- Preparing installation site p.4
- Preparation 4 p.4
- Preparation p.4
- Outdoor unit p.4
- Mounting the outdoor unit p.4
- Installation site requirements of the outdoor unit p.4
- Installation 4 p.4
- Installation p.4
- About this document p.4
- About the documentation 4 p.4
- About the documentation p.4
- To remove the accessories from the outdoor unit p.4
- About the box 4 p.4
- About the box p.4
- To provide the installation structure p.4
- Technical data 10 p.4
- Table of contents p.4
- Starting up the outdoor unit 9 p.4
- To provide drainage p.5
- To prevent the outdoor unit from falling over p.5
- To install the outdoor unit p.5
- To connect the refrigerant piping to the outdoor unit p.5
- Installation p.5
- Connecting the refrigerant piping p.5
- To determine if oil traps are required p.6
- To check for leaks p.6
- Installation p.6
- Checking the refrigerant piping p.6
- B a 4 ø6 mm p.6
- To perform vacuum drying p.7
- To fix the fluorinated greenhouse gases label p.7
- To determine the additional refrigerant amount p.7
- To charge refrigerant p.7
- Installation p.7
- Connecting the electrical wiring p.7
- Charging refrigerant p.7
- To connect the electrical wiring on the outdoor unit p.8
- Specifications of standard wiring components p.8
- Installation p.8
- About electrical compliance p.8
- To reposition the air thermistor on the outdoor unit p.9
- To finish the outdoor unit installation p.9
- Starting up the outdoor unit p.9
- Finishing the outdoor unit installation p.9
- A b c d e p.9
- Wiring diagram outdoor unit p.10
- Wiring diagram p.10
- Technical data p.10
- Service space outdoor unit p.10
- Technical data p.11
- Rotex heating systems sarl p.12
- Rotex heat i ng syst ems gmbh langwiesenstraße 10 d 74363 güglingen fon 49 7135 103 0 fax 49 7135 103 200 p.12
- P385895 1a p.12
- Errors and technical changes reserved 10 2010 p.12
- Daikin airconditioning uk ltd p.12
- Daikin airconditioning spain p.12
- Daikin airconditioning italy s p a p.12
- Daikin airconditioning belgium nv p.12
Похожие устройства
-
Daikin RRLQ016CAW1Руководство по применению для установщика -
Daikin RRLQ016CAW1Инструкция по монтажу -
Daikin RRLQ016CAW1Инструкция по эксплуатации -
Daikin RRLQ014CAW1Руководство по применению для установщика -
Daikin RRLQ014CAW1Инструкция по эксплуатации -
Daikin RRLQ011CAW1Руководство по применению для установщика -
Daikin RRLQ011CAW1Инструкция по монтажу -
Daikin RRLQ011CAW1Инструкция по эксплуатации -
Daikin RRLQ008CAV3Руководство по применению для установщика -
Daikin RRLQ008CAV3Инструкция по монтажу -
Daikin RRLQ008CAV3Инструкция по эксплуатации -
Daikin RRLQ006CAV3Руководство по применению для установщика
Подробное руководство по установке наружного блока теплового насоса. Узнайте о подготовке, монтаже и подключении, чтобы обеспечить эффективную работу устройства.