Daikin RZAG71L7V1B [2/20] Installation manual
![Daikin RZAG71L7V1B [2/20] Installation manual](/views2/1794865/page2/bg2.png)
1
1+2
1
A~E
a b c d e e
B
e
D
H
B
H
D
H
U
(mm)
a
b
c
d
e
e
B
e
D
A
B
C
D
E
H
B
H
U
H
D
B — ≥100
A, B, C — ≥100 ≥100 ≥100
B, E — ≥100 ≥1000 ≤500
A, B, C, E — ≥150 ≥150 ≥150 ≥1000 ≤500
D — ≥500
D, E — ≥1000 ≤500
≥500
≥500
≥500
B, D ≥100
≥100
B, D, E H
B
<H
D
H
B
<H
D
H
B
≤½H
U
≥250 ≥750 ≥1000 ≤500
½H
U
<H
B
≤H
U
≥250 ≥1000 ≥1000 ≤500
H
B
>H
U
H
D
>H
U
H
D
<H
U
H
B
>H
D
H
B
>H
D
H
B
<H
D
H
B
>H
D
H
D
≤½H
U
≥100 ≥1000 ≥1000 ≤500
½H
U
<H
D
≤H
U
≥200 ≥1000 ≥1000 ≤500
H
D
>H
U
H
U
a
b
≥100
≥100
c
d
e
e
B
e
D
A
B
C
D
E
H
B
H
D
A, B, C — ≥200 ≥300 ≥1000
A, B, C, E — ≥200 ≥300 ≥1000 ≥1000 ≤500
D — ≥1000
D, E — ≥1000 ≥1000 ≤500
B, D H
D
>H
U
≥300 ≥1000
H
D
≤½H
U
≥250 ≥1500
½H
U
<H
D
≤H
U
≥300 ≥1500
B, D, E H
B
<H
D
H
B
≤½H
U
≥300 ≥1000 ≥1000 ≤500
½H
U
<H
B
≤H
U
≥300 ≥1250 ≥1000 ≤500
H
B
>H
U
H
B
>H
D
H
D
≤½H
U
≥250 ≥1500 ≥1000 ≤500
½H
U
<H
D
≤H
U
≥300 ≥1500 ≥1000 ≤500
H
D
>H
U
1
b (mm)
H
B
≤½H
U
b≥250
½H
U
<H
B
≤H
U
b≥300
H
B
>H
U
H
B
H
U
≥1000
≥200
≥2000
≥100
≥3000
≥600
≥1500
b
≥100
≥100
≥100
≥100
≥100
≥100
H
B
H
U
2
A1
B1
A2
B2
A2
≥1000
A2
≥300
≥100
≥100
≥100
≥300
≥100
≥100
B2
≥100
≥1000
B2
3
Содержание
- Installation manual 1
- Split system air conditioners 1
- Installation manual 2
- 551 emc 3
- Aib vinçotte nb0026 3
- Daikin europe n v 3
- Daikin tcf 33 04 2016 3
- Daikin tcfp 01 3
- Dekra nb0344 3
- Electromagnetic compatibility 2014 30 eu 3
- En60335 2 40 3
- Low voltage 2014 35 eu 3
- Machinery 2006 42 ec 3
- P329110 6g 3
- Pressure equipment 2014 68 eu 19 07 2016 3
- Pressure equipment 97 23 ec 18 07 2016 3
- Rzag71l7v1b rzag100l7v1b rzag125l7v1b rzag140l7v1b 3
- Aib vinçotte international n v diamant building a reyerslaan 80 b 1030 brussels belgium 4
- P329110 6g 4
- Shigeki morita director ostend 1st of april 2016 4
- About the box 5
- About the box 5 5
- About the documentation 5
- About the documentation 5 5
- About this document 5
- Commissioning 12 5
- Installation 6 5
- Installation site requirements of the outdoor unit 5
- Outdoor unit 5
- Preparation 5
- Preparation 5 5
- Preparing installation site 5
- Table of contents 5
- Technical data 14 5
- To remove the accessories from the outdoor unit 5
- About the minimum floor area 6
- Installation 6
- Mounting the outdoor unit 6
- To determine the minimum floor area 6
- To install the outdoor unit 6
- To provide drainage 6
- To provide the installation structure 6
- B a 4 ø6 mm 7
- Connecting the refrigerant piping 7
- Installation 7
- To connect the refrigerant piping to the outdoor unit 7
- To prevent the outdoor unit from falling over 7
- Ø6 mm 7
- Checking refrigerant piping setup 8
- Checking the refrigerant piping 8
- Installation 8
- To check for leaks 8
- To determine if oil traps are required 8
- About charging refrigerant 9
- Charging refrigerant 9
- Installation 9
- To perform vacuum drying 9
- About the refrigerant 10
- Charging refrigerant setup 10
- Installation 10
- To charge refrigerant 10
- To determine the additional refrigerant amount 10
- To determine the complete recharge amount 10
- About electrical compliance 11
- Connecting the electrical wiring 11
- Guidelines when connecting the electrical wiring 11
- Installation 11
- Specifications of standard wiring components 11
- To connect the electrical wiring on the outdoor unit 11
- To fix the fluorinated greenhouse gases label 11
- A b c d e 12
- Checklist before commissioning 12
- Commissioning 12
- Finishing the outdoor unit installation 12
- To check the insulation resistance of the compressor 12
- To finish the outdoor unit installation 12
- Commissioning 13
- To perform a test run 13
- Error codes when performing a test run 14
- Service space outdoor unit 14
- Technical data 14
- Piping diagram outdoor unit 15
- Technical data 15
- Wiring diagram outdoor unit 15
- Technical data 16
- Ceiling mounted 19
- Ceiling mounted uni 19
- Floor standing 19
- Floor standing uni 19
- Wall mounted 19
- Wall mounted uni 19
- Copyright 2016 daikin 20
- P418662 1 20
Похожие устройства
- Daikin RZAG71L7V1B Руководство по применению для установщика
- Daikin RZAG71L7V1B Общие правила техники безопасности
- Alpine X903D-ID Инструкция по эксплуатации
- Alpine X903D-S906 Руководство пользователя
- Alpine X903D-S906 Инструкция по эксплуатации
- Daikin RZAG125L7V1B Инструкция по монтажу
- Daikin RZAG125L7V1B Общие правила техники безопасности
- Daikin RZAG125L7V1B Руководство по применению для установщика
- Daikin RZAG100L7V1B Инструкция по монтажу
- Daikin RZAG100L7V1B Общие правила техники безопасности
- Daikin RZAG100L7V1B Руководство по применению для установщика
- Alpine X903D-V447 Руководство пользователя
- Alpine X903D-V447 Инструкция по эксплуатации
- Daikin RZAG140L7V1B Инструкция по монтажу
- Daikin RZAG140L7V1B Общие правила техники безопасности
- Daikin RZAG140L7V1B Руководство по применению для установщика
- Alpine INE-F904D Руководство пользователя
- Alpine INE-F904D Инструкция по эксплуатации
- Alpine X903D-F Инструкция по эксплуатации
- Alpine X903D-F Руководство пользователя