Daikin FLOSTO150 [5/24] General
![Daikin FLOSTO150 [5/24] General](/views2/1797922/page5/bg5.png)
1 General safety precautions
Installation and operating instructions
5
Daikin FLOSTO150
Hot water storage tank
008.1632099_00 – 03/2019 – EN
These instructions provide all the necessary information for installa-
tion, commissioning and maintenance, as well as basic information
on operation and settings. Please see the attached documents for a
detailed description of operation and control.
Relevant documents
▪ When connecting to an external heat generator; the associated in-
stallation and operating instructions.
These instructions are included in the scope of supply for the indi-
vidual devices.
1.1.2 Meaning of warnings and symbols
Warnings in these instructions are classified according into their
severity and probability of occurrence.
DANGER
Indicates an immediate danger.
Disregarding this warning can lead to serious injury or
death
WARNING
Indicates a potentially dangerous situation
Disregarding this warning may result in serious physical in-
jury or death.
CAUTION
Indicates a situation which may cause possible damage
Disregarding this warning can cause damage to property
and the environment and result in minor injuries.
This symbol identifies user tips and particularly useful in-
formation, but not warnings or hazards
Special warning signs
Some types of danger are represented by special symbols.
Electric current
Risk of burning or scalding
Validity
Some information in these instructions has limited validity. The valid-
ity is highlighted by a symbol.
Comply with the stipulated tightening torque (see chap.)
Handling instructions
1 Handling instructions are shown as a list. Actions for which the
sequential order must be maintained are numbered.
è
Results of actions are identified with an arrow.
1.2 Safety instructions for installation
and operation
1.2.1 General
WARNING
Devices that have not been set up and installed correctly
can impair the function of the device and/or cause serious
or fatal injury to the user.
▪ Work on the device (e.g. set-up, inspection, connection
and initial commissioning) may only be carried out by
persons who are authorised and have successfully
completed qualifying technical or vocational train-
ing, enabling them to perform the respective activity and
who have participated in advanced training courses re-
cognised by the relevant competent authority. These in-
clude, in particular, certified heating engineers, quali-
fied electricians and HVAC specialists, who, because
of their professional training and their expert know-
ledge, have experience in the professional installation
and maintenance of heating systems, gas installations
and hot water tanks.
▪ Before starting any work on the device, switch off the ex-
ternal main switch and secure it against unintentional
switch-on.
▪ Do not leave any tools or other objects below the hood
of the device after finishing installation or maintenance
work.
Avoiding danger
The hot water storage tank is state of the art and is built to meet all
recognised technical requirements. However, improper use may res-
ult in serious physical injuries or death as well as property damage.
To avoid danger, only install and operate the device:
▪ as stipulated and in perfect condition,
▪ with an awareness of safety and the dangers involved.
This assumes knowledge and use of the contents of these operating
instructions, of the relevant accident prevention regulations as well
as the recognised safety-related and occupational health rules.
Before working on the heating system
▪ Only authorised and trained heating technicians may work on the
hot water storage tank (such as installation, connection and initial
commissioning).
▪ Switch off the external main switch before starting any work on the
hot water storage tank and secure it against unintentional switch-
on.
▪ Seals must not be damaged or removed.
▪ Make sure that the safety valves comply with the requirements of
EN12828 when connecting on the heating side, and with the re-
quirements of EN12897 when connecting on the domestic water
side.
▪ Only original replacement parts may be used.
1.2.2 Intended use
The device may only be used as a hot water storage tank. The
device must only be installed, connected and operated according to
the information in these operating instructions.
When connecting to an oil condensing boiler, only use the storage
tank connection kits provided for this purpose.
Only those electric immersion heaters supplied by the manufacturer
may be used.
Any other use outside the intended use is considered as improper.
The operator alone shall bear responsibility for any resulting dam-
age.
Содержание
- Flosto150 1
- Installation and 1
- Operating instructions 1
- Commissioning 14 3
- General safety precautions 4 3
- Handover to operator and warranty 7 3
- Hydraulic connection 16 3
- Inspection and maintenance 18 3
- Installation and operating instructions 3
- List of contents 3
- List of keywords 23 3
- Notes 22 3
- Product description 8 3
- Set up and installation 10 3
- Taking out of operation 15 3
- Technical data 20 3
- General safety precautions 4
- Observing the instructions 4
- Particular safety instructions 4
- General 5
- General safety precautions 5
- Intended use 5
- Meaning of warnings and symbols 5
- Safety instructions for installation and operation 5
- Device installation room 6
- Electrical installation 6
- General safety precautions 6
- Heating system and sanitary connection 6
- Operation 6
- Requirements for the filling water 6
- Handover to operator and warranty 7
- Instruct the owner 7
- Warranty conditions 7
- Design and components 8
- Product description 8
- Circulation brakes 9
- Circulation line connection 9
- Electric immersion heater 9
- External current anode 9
- Installing optional accessories 9
- Product description 9
- Scalding protection 9
- Storage tank connection kit 9
- Important information 10
- Installation 10
- Installing the hot water storage tank 10
- Scope of delivery 10
- Set up and installation 10
- Mounting removing the storage tank cladding 11
- Set up and installation 11
- Hydraulic system connection 12
- Important information 12
- Installation 12
- Set up and installation 12
- Filling topping up 13
- Hot water storage tanks 13
- Set up and installation 13
- Commissioning 14
- Draining the heating circuit 15
- Draining the storage tank 15
- Final shutdown 15
- Taking out of operation 15
- Temporary shutdown 15
- F b n o c o r 16
- Hydraulic connection 16
- Hydraulic system connection 16
- Mk1 mk2 16
- Rocon m1 16
- Hydraulic connection 17
- Mk1 mk2 17
- Annual inspection 18
- Cleaning 18
- Inspection and maintenance 18
- Inspection and maintenance 19
- Basic data 20
- Performance diagrams 20
- Technical data 20
- Technical data 21
- Tightening torques 21
- List of keywords 23
Похожие устройства
- Daikin FLOSTO150 Инструкция по монтажу
- Falcon Eye FE-SD90A/15M Инструкция по эксплуатации
- Falcon Eye FE-SDV88A/30M Инструкция по эксплуатации
- Falcon Eye FE-SDV90A/30M Инструкция по эксплуатации
- Falcon Eye FE-CC89 Инструкция по эксплуатации
- Falcon Eye FE DA82/10M Инструкция по эксплуатации
- Falcon Eye FE-DA90/10M Инструкция по эксплуатации
- Falcon Eye FE-MDV90/15M Инструкция по эксплуатации
- Falcon Eye FE-90Z Инструкция по эксплуатации
- Falcon Eye FE-B90A Инструкция по эксплуатации
- Falcon Eye FE-B90A/10M Инструкция по эксплуатации
- Falcon Eye FE-2204HDS Инструкция по эксплуатации
- Falcon Eye FE-101AVR Инструкция по эксплуатации
- Falcon Eye FE-MTR300 Инструкция по эксплуатации
- Tefal VS7001 Инструкция по эксплуатации
- Miele DG 4164 L Инструкция по установке
- Miele DG 4164 L Инструкция по эксплуатации
- Miele DG 5040 Инструкция по эксплуатации
- Miele DG 3460 Инструкция по эксплуатации
- Miele DG 3460 Руководство пользователя