General-Fujitsu ASH9ASGCW [10/23] Change of function by the diodes

General-Fujitsu ASH9ASGCW [10/23] Change of function by the diodes
– 12 –
K1
K2
K3
K6
K7
K10K14
K15
K8
D3
D8
D9
KEY NO. KEY FUNCTION
CORRESPONDENCE TABLE
No. KEY FUNCTION
K1 MASTER CONTROL
K2
SET TEMP. (
+
),SET TIME (
+
)
K3 FAN CONTROL
K4
K5
K6
SET TEMP. (), SET TIME ()
K7 AIR FLOW DIRECTION
K8 SWING LOUVER
K9
K10 START / STOP
K11
K12
K13
K14 SLEEP
K15 TIMER
K16
SW1 ACL
SW2 TIME ADJUST
SW3 TEST RUN
CHANGE OF FUNCTION BY THE DIODES
SET UP
No. FUNCTION MOUNTING
NO MOUNTING
DIODE DIODE
D3
TRANSMITTING CODE
FRONT BACK
SWITCHING
D4 HEATING MODE
D5 INVERTING SIGNAL
D6
TEMPERATURE DISPLAY OF
18–30°C ±2°C
AUTOMATIC OPERATION
D7 NO SWITCHING FUNCTION
D8 QUIET
D9 FAN MODE
D10 NO SWITCHING FUNCTION
Models : ASH9RSGCW
ASH12RSGCW
: Possible
: Impossible