Haier HSU-09H03/R(DB) [14/131] Outdoor unit

Haier HSU-09H03/R(DB) [14/131] Outdoor unit
4.2 Outdoor unit
Connectors PCB1˄control PCB˅
1˅ CN1 connector for CON20 in PCB2 for supply 310V
2˅ CN5/CN6/CN7/CN8 connector for suction/defrost/ambient/compressor sensor
3˅ CN11 connector for CN3 in PCB3
4˅ CN14 connector for electronic inflated valve
5˅ CN16 connector for CN5 in PCB3
6˅ P7/P8/CN12 connector for fan motor
7˅ P1 is grounded wiring
8˅ P5 connector for N(IN) in PCB3
9˅ P6 connector for L(IN) in PCB3
PCB2
1˅ CON20 connector for CN1 in PCB1
2˅ CON22 connector for N in PCB3˗
3˅ CON24 connector for Pin PCB3
4˅ CON21 connector for P˄OUT+˅in PCB3 ˗
5˅ CON24 connector for N˄OUT-˅in PCB3
PCB3
1˅ CN3 connector for CN11 in PCB1
2˅ CN5 connector for CN16 in PCB1
3˅ P/N is how to connect referring to PCB2
4˅ U/V/W connector for black/white/red wire of compressor
5˅ LX1/LX2 connector for inductance
6˅ P˄OUT+ ˅and N˄
OUT-
˅are how to connect referring to PCB2
7˅ L˄IN˅and N˄IN˅are how to connect referring to PCB1