Haier HSU-07HM03 [16/42] Operation

Содержание

Operation Emergency operation and test operation Emergency operation Carry out this operation only when the remote controller is defective or lost When the emergency operation switch is pressed a Pi sound starts once which means the start of this operation In this operation it is not possible to change the settings of temperature and airflow speed it is also impossible to do an operation by the timer Follow the requirements below Room temperature Designated temperature Timer mode Air flow speed Operation mode More than 23 C 26 C CONTINUOUS AUTO COOL Less than 23 C 23 C CONTINUOUS AUTO HEAT If an air conditioner is a model for both cooling and heating Cooling when the room temperature at the start of operation is above 23 C Heating when the room temperature at the start of operation is less 23 C Test operation Use this switch in the test operation when the room temperature is less 16 C do not use it in the normal operation Continue to press the test operation switch for more than 5 seconds After you hear the Pi sound twice release your finger from the switch the cooling operation starts with the air flow speed setting Hi Removal of the restriction of emergency or test operation Press once more the emergency operation switch or manipulate through the remote controller a Pi sound causes the restriction of emergency or test operation to be removed When the remote controller is manipulated for the removal then the selected operation by the remote controller 14

Скачать