Step 1 Preparation Required Tools for Installation Choose a place solid enough to bear the weight of the unit Avoid choosing a site with steam or heat When mounting the unit always maintain proper clearances Position so that the condensate can easily drain An area where the piping can be connected with the outdoor unit Where airflow can blow evenly throughout the room Place a minimum distance of 3 ft from televisions radios wireless apparatuses and fluorescent lamps When mounting the remote controller on a wall position it where the indoor unit can receive the remotes infrared signals when fluorescent lamps in the room are in use There must be sufficient space for air passage and no obstructions around the air inlet and air outlet The site must be free from the possibility of flammable gas leakage in a nearby place Note 1 R 410A refrigerant is a safe nontoxic and nonflammable refrigerant However if there is a concern about a dangerous level of refrigerant concentration in the case of refrigerant leakage add extra ventilation Clearances of Indoor and Outdoor Units This picture is for reference only Your product may look different Read this manual before installation Explain the operation of the unit to the user according to this manual The models adopt HFC free refrigerant R410A Attention must be paid to the rising up ot drain hose more than 4 in more than 4 in Outdoor unit mounting dimensions Unit mm inch L JU Arrangement of piping directions For 09k 12k 18k more than 4 in Rear left Rear right 12k 18k 140mm 4 1B 113 5 mm 19 is 500mm 22 15 1S 583mm 10 ns 256mm Right Below 12 6 319 5mm more than 8 in more than 6 in j Mounting the Outdoor Unit Mount the unit to concrete or a block with bolts 10mm and nuts firmly and horizontally When mounting the unit to a wall or roof take strong winds and other environmental conditions into consideration when securing If vibrations effect the house mount the unit using a vibration proof mat The marks from to in the figure are the parts numbers The distance between the indoor unit and the floor should be more than 6 5 ft more than 24 in Single zone outdoor unit shown for illustration purposes ONLY INSTALLATION more than 10 in PAGE 21 ENGLISH Drill Wire Snipper Hole Saw 2 3 4 Vacuum pump Soap and water solution or gas leakage detector Torque wrench 17mm 22mm 26mm Tubing cutter Flaring tool Razor knife Measuring tape Level Micron gauge Nitrogen Mini Split AD 87 Adapter 1 4 to 5 16 A Non adhesiveTape B Ad hesive Ta pe C Saddle L S with screws D Electrical wiring E Drain hose Included F Insulation G Piping hole cover Included Procedure for Selecting the Location

Скачать