Haier HSM-08C03/R1 [12/16] Operation guide

Operation Guide Power supply A reliable grounding Before plug in the receptacle please check The voltage range of the air conditionder is 220 10 V too high or low voltage will make a bad effect on the air The power cord is suitable to a starting current of over 20A to avoid sudden voltage drop when the air condi tioner is started The plug and recepatacle air conditioner used should endure a current of over 13 A The power consumption among the air conditioner other home appliance and lighting circuits should not make the breaker to trip The cross section area of the power cord and any expansion cord should be no less than 1 5mm2 If the power cord of the air conditioner is damaged it must be replaced with the special cord A reliable grounding should be used The grounding wire should be connected with the special apparatus of the building to guarantee the air conditioner has a good grounding Fig 2 Don t use the steel and copper cord to replace the fuse The capacity of the fuse should be appropriate Don t fix the power cord on a sharp structure to avoid damaging of the cord and danger of electric shock The wiring method should be in line with the national wiring standard When wiring a protector and air breaker having enough capacity should be used Do not connect the grounding wire with the tap or gas pipe When the air conditioner is not in use please pull out the power plug to switch the power off Fig 2 Fig 3 11 Fig 3