Haier HSM-08C03/R1 [13/16] Cleaning of air filter
Содержание
- Split mobile air conditioner 1
- Working principle 2
- The machine is adaptive in following situation 3
- The operation principle of split mobile type air conditioner 3
- Working principle 3
- Control panel 5
- Description of the components 5
- Lcd window 5
- Description of the components 6
- Illi illi illi illi illi illi 6
- Application of cooling and dehumidifying 7
- Dehumidifying 7
- Fan running 7
- L cooling 7
- Placing requirements 7
- Automatic louver function 8
- Drainage 8
- Remarks 8
- Sleep function 8
- Timing function 8
- Air purifying function 9
- Remarks 9
- Points for attention 10
- Installation 11
- Operation guide 12
- Power supply 12
- Attention 13
- Cleaning of air filter 13
- Cleaning of the air conditioner 13
- Maintenance 13
- Mobile air conditioner 13
- Precaution 13
- Remark per emc directive 89 336eec 13
- Connecting of pipe 14
- Accessories 15
- Precautions 15
- The methods of continuous drainage 15
- The methods of solving abnormal condition 16
Похожие устройства
- Dialog Gan-Kata KGK-45U Руководство пользователя
- Haier HM-07C03 Сервис мануал
- Haier HM-07C03 Инструкция по эксплуатации
- Dialog Katana KK-ML17U Руководство пользователя
- Dialog Standart KS-020P Руководство пользователя
- Dialog Standart KS-020U Руководство пользователя
- Philips SPZ5000 Краткое руководство
- Philips SPZ5000 Руководство пользователя
- Hotpoint-Ariston 7OFK 637J RU/HA Инструкция по эксплуатации
- Hotpoint-Ariston 7OFK 637J X RU/HA Инструкция по эксплуатации
- Hotpoint-Ariston 7OFK 637J C RU/HA Инструкция по эксплуатации
- Hotpoint-Ariston 7OFK 638J RU/HA Инструкция по эксплуатации
- Harman/Kardon CA-280E Service manual
- Dialog KMGK-1707U Руководство пользователя
- Dialog GW-125VR Руководство пользователя
- Dialog GW-135VR Руководство пользователя
- Dialog GW-155VR Руководство пользователя
- Dialog GW-225VR Руководство пользователя
- Dialog GW-235VR Руководство пользователя
- Dialog GW-255VR Руководство пользователя
Maintenance MOBILE AIR CONDITIONER The split mobile type air coditioner is equipped with foot wheels It can be easily moved in room as your desire When moving the out door unit can be moved hung on the indoor unit Before moving empty the water in the water tank firstly PRECAUTION Before any repair and maintenance the power plug should be firstly pulled out from the receptacle and switch off the power supply Only after cut off can repair and maintenance be made to avoid electric shock CLEANING OF AIR FILTER The air filter can absorb a large amount of the impurity of the air dust pollen bacteria etc so it must be cleaned regularly at least once a week Hold the edge of the air inlet and remove it thus the air filter is removed and ready to be cleaned When cleaning jet water as sJL used in bathroom can be used to rinse and shave thd air g M filter It can also be damped into the warm soap water place it on after dried f J Rif CLEANING OF THE AIR CONDITIONER Using soap or detergent to clean the outdoor unit Don t use gasoline diesel oil or other things alike Before cleaning please pull the power cord out first After 1 2 years of using there will be dirty things blocking the condenser affecting the efficency of the air conditioner At this time please contact our service centre Remark per EMC Directive 89 336EEC To prevent flicker impression during the start of the compressor Technical Process following installation conditions do apply 1 The power connection for the air conditioner has to be done at the main power distribution This distribution has to be of a low impedance Normally the required impedance is reached at a 32A fusing point 2 No other equipment has to be connected to this power line 3 For the detailed installation acceptance please refer to your contract with the power supplier if restrictions do apply for products like washing machines air conditioners or electrical ovens 4 For the details of the power of air conditioner please refer to the rating plate of the product 5 For any question contact your local dealer Attention Through poor conditions of the electrical MAINS shortly voltage drops can appear when starting the EQUIPMENT This can influence other equipment eg Blinking of a lamp If the MAINS IMPEDANCE Zmax 0 331 OHM such disturbances are not expected In case of need you may contact your local supply authority for further in formation 12