1. GENERAL INFORMATION
• Read the warnings in this instruction booklet carefully since they provide important
information on safe installation, use and maintenance.
• This instruction booklet is an integral and essential part of the product and must be
kept with care by the user for future reference.
• If the unit is sold or transferred to another owner or if it is to be moved, always make
sure the booklet stays with the boiler so that it can be consulted by the new owner
and/or installer.
• Installation and maintenance must be carried out by professionally qualified person-
nel, according to current regulations and the manufacturer's instructions.
• Incorrect installation or inadequate maintenance can result in damage or injury. The
manufacturer declines any liability for damage caused by errors in installation and
use or by failure to follow the instructions provided.
• Before carrying out any cleaning or maintenance operation, disconnect the unit from
the power supply using the system switch and/or the special cut-off devices.
• In case of a fault and/or poor operation, deactivate the unit and do not try to repair
it or directly intervene. Contact professionally qualified personnel. Any repair/re-
placement of the products must only be carried out by qualified personnel using gen-
uine parts. Failure to comply with the above can compromise the safety of the unit.
• Periodic maintenance performed by qualified personnel is essential in order to en-
sure proper operation of the unit.
• This unit must only be used for its intended purpose. Any other use is deemed im-
proper and therefore hazardous.
• After unpacking, check the good condition of the contents. The packing materials
are potentially hazardous and must not be left within the reach of children.
• The unit can be used by children aged at least 8 years and by persons with reduced
physical, sensory or mental capabilities, or lacking experience or the necessary
knowledge, only if under supervision or they have received instructions on its safe
use and the related risks. Children must not play with the unit. Cleaning and main-
tenance intended to be done by the user can be carried out by children aged at least
8 years only if under supervision.
• In case of doubt, do not use the unit. Contact the supplier.
• The unit and its accessories must be appropriately disposed of in compliance with
current regulations.
• The images given in this manual are a simplified representation of the product. In
this representation there may be slight and insignificant differences with respect to
the product supplied.
2. OPERATING INSTRUCTIONS
2.1 Introduction
Dear Customer,
FL D HF is a high-efficiency sealed chamber heat generator for heating and hot water
production (optional) running on natural gas or LPG, and equipped with a microproces-
sor control system.
A
The boiler is arranged for connection to an external storage tank for hot
water (optional). In this manual all the functions relevant to domestic hot
water production are only active with the optional hot water tank connect-
ed as indicated in sec. 3.3
2.2 Control panel
Panel
fig. 1 - Control panel
Key of panel fig. 1
1 DHW temperature setting decrease button
2 DHW temperature setting increase button
3 Heating system temperature setting decrease button
4 Heating system temperature setting increase button
5 Display
6 "Sliding Temperature" Menu - Summer/Winter mode selection - Reset button
7 Unit On/Off - Economy/Comfort mode selection button
8 DHW symbol
9 DHW mode
10 Summer mode
11 Multifunction
12 Eco (Economy) mode
13 Heating
14 Heating symbol
15 Burner lit and actual power level (flashing during combustion fault function)
16 Service Tool connection
17 Water gauge
Indication during operation
Heating
A heating demand (generated by the Room Thermostat or Remote Timer Control) is in-
dicated by flashing of the hot air above the radiator on the display.
The display (detail 11 - fig. 1) shows the actual heating delivery temperature and, during
heating standby time, the message “d2”.
Domestic hot water (DHW)
A DHW demand (generated by drawing domestic hot water) is indicated by flashing of
the hot water under the tap on the display.
The display (detail 11 - fig. 1) shows the actual DHW outlet temperature and, during
DHW standby time, the message “d1“.
Comfort
A Comfort demand (reinstatement of temperature inside the boiler) is indicated by flash-
ing of the water under the tap on the display. The display (detail 11 - fig. 1) shows the
actual temperature of the water in the boiler.
Fault
In case of a fault (see cap. 4.4) the display shows the fault code (detail 11 - fig. 1) and
during safety pause times the messages “d3”, “d4” and “d5”.
2.3 Lighting and shutdown
Connection to the power supply
• During the first 5 seconds the display will also show the card software release.
• Open the gas cock ahead of the boiler.
• The boiler is now ready to function automatically whenever domestic hot water is
drawn or in case of a heating demand (generated by Room Thermostat or Remote
Temperature Control).
Turning the boiler off and on
Press the on/off button (detail 7 - fig. 1) for 5 seconds.
fig. 2 - Turning the boiler off
When the boiler is turned off, the circuit board is still powered. Domestic hot water and
heating are disabled. The frost protection system remains activated. To relight the boiler,
press the on/off button (detail 7 fig. 1) again for 5 seconds.
fig. 3
The boiler will be immediately ready to work whenever domestic hot water is drawn or in
case of a heating demand (generated by the Room Thermostat or the Remote Timer
control).
B
The frost protection system does not work when the power and/or gas to the
unit are turned off. To avoid damage caused by freezing during long shutdowns
in winter, it is advisable to drain all water from the boiler, the DHW circuit and
the heating system water; or drain just the DHW circuit and add a suitable an-
tifreeze to the heating system, as prescribed in sec. 3.3.
THE CE MARKING CERTIFIES THAT THE PRODUCTS MEET THE ESSENTIAL REQUIREMENTS
OF THE RELEVANT DIRECTIVES IN FORCE.
THE DECLARATION OF CONFORMITY MAY BE REQUESTED FROM THE MANUFACTURER.
0
1
4
2
3
reset
eco
comfort
9
15
13
12
11
8
1
36
7102
16414
5
17
Содержание
- Instructions for use installation and maintenance 1
- Fl d hf 2
- Fl d hf 3
- Fl d hf 4
- Fl d hf 5
- Fl d hf 6
- Fl d hf 7
- Cod 3541p701 rev 00 10 2018 8
- Configuration menu 8
- Fl d hf 8
- Heating power adjustment 8
- If the test mode is activated and enough hot water is drawn to activate the dhw mode the boiler remains in test mode but the 3 way valve goes to dhw 8
- Parameters indicated by the letter p are available which are also modifiable from remote timer control 8
- Parameters with more than one description vary their function and or range in rela tion to the setting of the parameter given in brackets 2 parameters with more than one description are reset to the default value if the pa rameter given in brackets is modified 8
- Press the heating buttons to scroll the list of parameters in increasing or decreasing or der press the dhw buttons to view or modify the value of a parameter the change will be automatically saved 8
- Service menu 8
- The card service menu is accessed by pressing the reset button for 20 seconds 4 sub menus are available press the heating buttons to select in increasing or decreasing or der ts in hi or re ts means transparent parameters menu in means information menu hi means history menu after selecting the submenu press the re set button again to access it re means history menu reset see description 8
- The configuration menu is accessed by pressing the dhw buttons together for 10 sec onds 12 parameters indicated by the letter b and not modifiable from remote timer control are available 8
- The test mode is automatically deactivated in any case after 15 minutes or on stopping of hot water drawing if enough hot water has been drawn to activate the dhw mode 8
- To adjust the heating power switch the boiler to test mode see sec 4 press the heating buttons detail 3 fig 1 to increase or decrease the power min 00 max 100 press the reset button within 5 seconds and the max power will remain that just set exit test mode see sec 4 8
- To deactivate the test mode press the heating buttons details 3 and 4 fig 1 together for 5 seconds 8
- To exit the configuration menu press the dhw buttons together for 10 seconds or exiting occurs automatically after 2 minutes 8
- Ts transparent parameters menu 8
- Fl d hf 9
- Cod 3541p701 rev 00 10 2018 10
- Diagnostics 10
- Fl d hf 10
- List of faults 10
- Other faults cause temporary shutdowns marked with the letter f which are automat ically reset as soon as the value returns within the boiler s normal working range 10
- Table 8 10
- Table 9 legend fig 27 fig 28 and fig 29 10
- Technical data and characteristics 10
- The boiler has an advanced self diagnosis system in case of a boiler fault the display will flash together with the fault symbol detail 11 fig 1 indicating the fault code 10
- There are faults that cause permanent shutdowns marked with the letter a to restore operation press the reset button detail 6 fig 1 for 1 second or reset on the op tional remote timer control if installed at this point the display will show d4 for about 30 seconds or d5 for about 5 minutes which indicates the waiting time after which the boiler will resume normal operation if the boiler fails to restart it is necessary to eliminate the fault 10
- Troubleshooting 10
- Fl d hf 11
- Fl d hf 12
- Fl d hf 13
- Fl d hf 14
- Fl d hf 15
- Fl d hf 16
- Fl d hf 17
- Fl d hf 18
- Fl d hf 19
- Fl d hf 20
- En 1856 1 21
- Fl d hf 21
- Fl d hf24 fl d hf32 21
- Fl d hf 22
- Cod 3541p701 rev 00 10 2018 23
- Fl d hf 23
- Fl d hf 24
- 9 27 28 29 25
- A 6 1 1 d4 30 d5 5 25
- Cod 3541p701 rev 00 10 2018 25
- Fl d hf 25
- Fl d hf 26
- Fl d hf 27
- Fl d hf 28
- Fl d hf 29
- Fl d hf 30
Похожие устройства
- Lamborghini FL D H F32 Каталог запчастей
- Lamborghini FL D H F32 Каталог
- Haier HW-18CB03 Инструкция по эксплуатации
- Haier HW-09C04 Инструкция по эксплуатации
- Haier HW-09HA04 Инструкция по эксплуатации
- Haier HW-12C04 Инструкция по эксплуатации
- Haier HW-07CA12 Инструкция по эксплуатации
- Haier HW-08C12 Инструкция по эксплуатации
- Haier HW-09C12 Инструкция по эксплуатации
- Haier HW-10C12 Инструкция по эксплуатации
- Haier HW-12C12 Инструкция по эксплуатации
- Haier HW-08C13 Инструкция по эксплуатации
- Haier HW-12C13 Инструкция по эксплуатации
- Haier HW-18C13(T3) Инструкция по эксплуатации
- Haier HW-18CA13 Инструкция по эксплуатации
- Haier AW094AAMAA Инструкция по эксплуатации
- Haier AW098AAAAA Инструкция по эксплуатации
- Haier AW122AGMAA Инструкция по эксплуатации
- Haier HW-12CC03 Инструкция по эксплуатации
- Haier AU96NXTAAA Инструкция по эксплуатации