4. SERVICE AND MAINTENANCE
Important
B
All adjustment, conversion, commissioning and maintenance operations
described below must only be carried out by Qualified Personnel (meet-
ing the professional technical requirements of current regulations) such
as the personnel of the Local After-Sales Technical Service.
LAMBORGHINI declines any liability for damage and/or injury caused by
unqualified and unauthorized persons tampering with the unit.
4.1 Adjustments
Gas conversion
B
ALL COMPONENTS DAMAGED DURING CONVERSION OPERATIONS
MUST BE REPLACED.
The unit can operate on natural gas or LPG and is factory-set for use with one of these
two gases, as clearly shown on the packing and on the data plate. Whenever a gas dif-
ferent from that for which the unit is arranged has to be used, the special conversion kit
will be required, proceeding as follows:
1. Disconnect the boiler power supply and close the gas cock.
2. Replace the nozzles at the main burner, fitting the nozzles specified in the technical
data table in cap. 5, according to the type of gas used
3. Switch the boiler power on and open the gas cock.
4. Modify the parameter for the type of gas:
• put the boiler in standby mode
• press the DHW buttons details 1 and 2 - fig. 1 for 10 seconds: the display shows
“b01“ flashing.
• press the DHW buttons details 1 and 2 - fig. 1 to set the parameter 00 (for nat-
ural gas operation) or 01 (for LPG operation).
• press the DHW buttons details 1 and 2 - fig. 1 for 10 seconds.
• the boiler will return to standby mode
5. Adjust the minimum and maximum pressures at the burner (ref. relevant para-
graph), setting the values given in the technical data table for the type of gas used
6. Apply the sticker contained in the conversion kit, near the data plate as proof of the
conversion.
Activation of Auto-setting function for gas valve calibration
THIS PROCEDURE MUST ONLY BE CARRIED OUT IN THE FOLLOWING CASES:
GAS VALVE REPLACEMENT, CARD REPLACEMENT, CONVERSION FOR GAS
CHANGE.
The B&P Gas Valve (with integrated modulating operator) does not provide for mechan-
ical calibration: the minimum and maximum power adjustments are therefore electroni-
cally done via two parameters:
Gas valve pre-calibration
1. Connect a pressure gauge to monitor the gas valve outlet pressure.
2. Enable the Auto-setting function (Parameter b12=1).
3. Activate the calibration procedure by pressing the heating + button and Eco/Comfort
button together for 5 seconds. The message "Au-to" immediately appears (in two
successive flashes) and the burner is lit. Within 8 seconds (natural gas and LPG)
the boiler finds the ignition point. The ignition point, absolute minimum current Offset
(Parameter q01) and absolute maximum current Offset (Parameter q02) values are
stored by the card.
Gas valve calibration
1. The display will show "q02" flashing; the modulation current is forced to the pre-cal-
ibration value of the absolute maximum current Offset parameter (Parameter q02).
2. Press the DHW buttons to adjust the parameter "q02" until the maximum nominal
pressure minus 1mbar is reached on the pressure gauge. Wait 10 seconds for the
pressure to stabilise.
3. Press the DHW “+” button to set the parameter “q02” until the maximum nominal
pressure is reached on the pressure gauge. Wait 10 seconds for the pressure to sta-
bilise.
4. If the pressure read on the pressure gauge is different from the maximum nominal
pressure, proceed in increments of 1 or 2 units of the parameter "q02" by pressing
the DHW “+” button: after each change, wait 10 seconds for the pressure to stabi-
lise.
5. When the pressure read on the pressure gauge is equal to the maximum nominal
pressure (the newly calibrated value of the parameter "q02" is automatically saved),
press the heating “–” button: the display will show "q01" flashing; the modulation
current is forced to the pre-calibration value of the absolute minimum current Offset
parameter (Parameter q01).
6. Press the DHW buttons to adjust the parameter "q01" until the minimum nominal
pressure plus 0.5mbar is reached on the pressure gauge. Wait 10 seconds for the
pressure to stabilise.
7. Press the DHW “-” button to adjust the parameter "q01" until the minimum nominal
pressure is reached on the pressure gauge. Wait 10 seconds for the pressure to sta-
bilise.
8. If the pressure read on the pressure gauge is different from the minimum nominal
pressure, proceed in decrements of 1 or 2 units of the parameter “q01” by pressing
the DHW “-” button: after each change, wait 10 seconds for the pressure to stabi-
lise.
9. When the pressure read on the pressure gauge is equal to the minimum nominal
pressure (the newly calibrated value of the parameter "q01" is automatically saved.),
recheck both adjustments by pressing the heating buttons and correct them if nec-
essary by repeating the procedure described above.
10. The calibration procedure ends automatically after 15 minutes or by pressing the
heating “+”
and Eco/Comfort buttons together for 5 seconds.
Checking of gas pressure values and adjustment with limited range
• Check that the supply pressure complies with that indicated in the technical data table.
• Connect a suitable pressure gauge to the pressure sampling point “B” located
downstream from the gas valve.
• Activate the TEST mode and follow the instructions for checking the gas pressures
at maximum power and minimum power (see next par.).
If the maximum and/or minimum nominal pressures read on the pressure gauge are dif-
ferent from those indicated in the technical data table, proceed with the next sequence.
• Press the Eco/Comfort button for 2 seconds to go to the gas valve Calibration with
limited range mode.
• The card goes to the setting “q02”; displaying the currently saved value by pressing
the DHW buttons.
•If the maximum pressure read on the pressure gauge is different from the nominal
one, proceed in increments/decrements of 1 or 2 units of the parameter “q02” by
pressing the DHW buttons: after each change, the value is stored; wait 10 seconds
for the pressure to stabilise.
• Press the heating “-” button (ref. 3 - fig. 1).
• The card goes to the setting “q01”; displaying the currently saved value by pressing
the DHW buttons.
•If the minimum pressure read on the pressure gauge is different from the nominal
one, proceed in increments/decrements of 1 or 2 units of the parameter “q01” by
pressing the DHW buttons: after each change, the value is stored; wait 10 seconds
for the pressure to stabilise.
• Recheck both settings by pressing the heating buttons and if necessary correct
them by repeating the procedure described above.
• Pressing the Eco/Comfort button for 2 seconds returns to TEST mode.
•Deactivate TEST mode (see next par.).
• Disconnect the pressure gauge.
TEST mode activation
Press the heating buttons (details 3 and 4 - fig. 1) together for 5 seconds to activate the
TEST mode. The boiler lights at the maximum heating power set as described in the fol-
lowing section.
The heating and DHW symbols (fig. 19) flash on the display; the heating power will ap-
pear alongside.
fig. 19 - TEST mode (heating power = 100%)
Press the heating buttons (details 3 and 4 - fig. 1) to increase or decrease the power
(Min.=0%, Max.=100%).
By pressing the DHW “-” button (detail 1 - fig. 1), boiler output is immediately adjusted
to min. (0%). By pressing the DHW “+” button (detail 2 - fig. 1), boiler output is immedi-
ately adjusted to max. (100%).
Contents Description Natural Gas Propane Gas
q01
Absolute minimum current offset 0÷100 0÷150
q02
Absolute maximum current offset 0÷100 0-150
fig. 17 - Gas valve
A
- Upstream pressure point
B
- Downstream pressure point
I
- Gas valve electrical connection
R
- Gas outlet
S
- Gas inlet
fig. 18 - Gas valve connection
TYPE SGV100
Pi max 65 mbar
24 Vdc - class B+A
R
B
I
A
S
~ 65W~ 24W
1 2 3 4
0
1
4
2
3
reset
eco
comfort
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
Содержание
- Instructions for use installation and maintenance 1
- Fl d hf 2
- Fl d hf 3
- Fl d hf 4
- Fl d hf 5
- Fl d hf 6
- Fl d hf 7
- Cod 3541p701 rev 00 10 2018 8
- Configuration menu 8
- Fl d hf 8
- Heating power adjustment 8
- If the test mode is activated and enough hot water is drawn to activate the dhw mode the boiler remains in test mode but the 3 way valve goes to dhw 8
- Parameters indicated by the letter p are available which are also modifiable from remote timer control 8
- Parameters with more than one description vary their function and or range in rela tion to the setting of the parameter given in brackets 2 parameters with more than one description are reset to the default value if the pa rameter given in brackets is modified 8
- Press the heating buttons to scroll the list of parameters in increasing or decreasing or der press the dhw buttons to view or modify the value of a parameter the change will be automatically saved 8
- Service menu 8
- The card service menu is accessed by pressing the reset button for 20 seconds 4 sub menus are available press the heating buttons to select in increasing or decreasing or der ts in hi or re ts means transparent parameters menu in means information menu hi means history menu after selecting the submenu press the re set button again to access it re means history menu reset see description 8
- The configuration menu is accessed by pressing the dhw buttons together for 10 sec onds 12 parameters indicated by the letter b and not modifiable from remote timer control are available 8
- The test mode is automatically deactivated in any case after 15 minutes or on stopping of hot water drawing if enough hot water has been drawn to activate the dhw mode 8
- To adjust the heating power switch the boiler to test mode see sec 4 press the heating buttons detail 3 fig 1 to increase or decrease the power min 00 max 100 press the reset button within 5 seconds and the max power will remain that just set exit test mode see sec 4 8
- To deactivate the test mode press the heating buttons details 3 and 4 fig 1 together for 5 seconds 8
- To exit the configuration menu press the dhw buttons together for 10 seconds or exiting occurs automatically after 2 minutes 8
- Ts transparent parameters menu 8
- Fl d hf 9
- Cod 3541p701 rev 00 10 2018 10
- Diagnostics 10
- Fl d hf 10
- List of faults 10
- Other faults cause temporary shutdowns marked with the letter f which are automat ically reset as soon as the value returns within the boiler s normal working range 10
- Table 8 10
- Table 9 legend fig 27 fig 28 and fig 29 10
- Technical data and characteristics 10
- The boiler has an advanced self diagnosis system in case of a boiler fault the display will flash together with the fault symbol detail 11 fig 1 indicating the fault code 10
- There are faults that cause permanent shutdowns marked with the letter a to restore operation press the reset button detail 6 fig 1 for 1 second or reset on the op tional remote timer control if installed at this point the display will show d4 for about 30 seconds or d5 for about 5 minutes which indicates the waiting time after which the boiler will resume normal operation if the boiler fails to restart it is necessary to eliminate the fault 10
- Troubleshooting 10
- Fl d hf 11
- Fl d hf 12
- Fl d hf 13
- Fl d hf 14
- Fl d hf 15
- Fl d hf 16
- Fl d hf 17
- Fl d hf 18
- Fl d hf 19
- Fl d hf 20
- En 1856 1 21
- Fl d hf 21
- Fl d hf24 fl d hf32 21
- Fl d hf 22
- Cod 3541p701 rev 00 10 2018 23
- Fl d hf 23
- Fl d hf 24
- 9 27 28 29 25
- A 6 1 1 d4 30 d5 5 25
- Cod 3541p701 rev 00 10 2018 25
- Fl d hf 25
- Fl d hf 26
- Fl d hf 27
- Fl d hf 28
- Fl d hf 29
- Fl d hf 30
Похожие устройства
- Lamborghini FL D H F32 Каталог запчастей
- Lamborghini FL D H F32 Каталог
- Haier HW-18CB03 Инструкция по эксплуатации
- Haier HW-09C04 Инструкция по эксплуатации
- Haier HW-09HA04 Инструкция по эксплуатации
- Haier HW-12C04 Инструкция по эксплуатации
- Haier HW-07CA12 Инструкция по эксплуатации
- Haier HW-08C12 Инструкция по эксплуатации
- Haier HW-09C12 Инструкция по эксплуатации
- Haier HW-10C12 Инструкция по эксплуатации
- Haier HW-12C12 Инструкция по эксплуатации
- Haier HW-08C13 Инструкция по эксплуатации
- Haier HW-12C13 Инструкция по эксплуатации
- Haier HW-18C13(T3) Инструкция по эксплуатации
- Haier HW-18CA13 Инструкция по эксплуатации
- Haier AW094AAMAA Инструкция по эксплуатации
- Haier AW098AAAAA Инструкция по эксплуатации
- Haier AW122AGMAA Инструкция по эксплуатации
- Haier HW-12CC03 Инструкция по эксплуатации
- Haier AU96NXTAAA Инструкция по эксплуатации