Panasonic CS-A18BKP / CU-A18BKP5 [35/82] Convenience operation
![Panasonic CS-A18BKP / CU-A18BKP5 [35/82] Convenience operation](/views2/1832887/page35/bg23.png)
● Operation Details
COOL – Cooling Operation
• To set the room temperature at your preference
cooling comfort.
AUTO – Automatic Operation
• Sense indoor temperature to select the optimum
mode.
• Temperature is not displayed on the remote control
during AUTO operation.
DRY – Soft Dry Operation
• A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.
• During Soft Dry operation, the indoor fan operates at
Low fan speed.
HEAT – Heating Operation
(for Heat Pump Model only)
• Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
falls, the heating capacity of the unit might be
reduced.
• Defrosting Operation
Depend on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
unit.
FAN – Air Circulation Operation
(for Cooling Model only)
• When the room temperature reaches the set
temperature, operation commences at Low airflow
volume. It stops when the room temperature drops to
2°C below the set temperature.
(It is useful when using a heater).
■ Setting the Fan Speed
• Press 4 to select:-
FAN – Low Fan Speed
FAN – Medium Fan Speed
FAN – High Fan Speed
AUTO
FAN – Automatic Fan Speed
The speed of the indoor fan is adjusted
automatically according to the operation.
The indoor fan stops occasionally during
cooling operation.
■ Setting the Vertical Airflow Direction.
• Press 5 to select:-
● Use this air conditioner under the following
conditions:
● Notes
• If the unit is not going to be used for an extended
period of time, turn off the main power supply. If it is
left at the ON position, approximately 2.5 W of
electricity will be used even if the indoor unit has been
turned off with the remote control.
• If operation is stopped, then restart immediately, the
unit will resume operation only after 3 minutes.
Heat Pump Model
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
Maximum Temperature
Minimum Temperature
WBT
23
11
DBT
43
16
WBT
26
11
Indoor Outdoor
(Unit in °C)
DBT
32
16
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
Maximum Temperature-Cooling
(Maximum Temperature-Heating)
Minimum Temperature-Cooling
(Minimum Temperature-Heating)
DBT
32
(30)
16
(16)
WBT
23
(-)
11
(-)
DBT
43
(24)
16
(-5)
WBT
26
(18)
11
(-6)
Indoor
Outdoor
(Unit in °C)
Cooling Model
AUTO
• For COOL/DRY operation.
Swing up/down automatically.
• For HEAT operation
(For Heat Pump Model only)
When the discharge air temperature is
low such as at the start of the heating
operation, the air blows at horizontal
level. As the temperature rises, the hot
air blows in a downwards direction.
AUTO
AUTO
■ Setting the Horizontal Airflow Direction.
• Press 6 to select:-
AUTO
Horizontal
Airflow
Direction
Indoor
Unit
Remote
Control
• For COOL/DRY operation.
Swing left/right automatically.
• For HEAT operation
(For Heat Pump Model only)
There is no air swing during the discharge
air temperature is low. When the
temperature rises, the horizontal airflow
louvers swing left/right automatically.
AUTO
AUTO
SETTING THE TIMER
Ensure that the current time is correct before setting the
timer. The timer cannot be set if the time display is
flashing.
■ ON-TIMER Operation
To start the air conditioner operation automatically.
• Press 1 to set the operation.
• Press 2 to increase or decrease the time.
• Then press 3.
• To cancel this operation, press 4.
■ OFF-TIMER Operation
To stop the air conditioner operation automatically.
• Press 5 to set the operation.
• Press 2 to increase or decrease the time.
• Then press 3.
• To cancel this operation, press 4.
● Timer Mode Operation Details
• When the ON-Timer is set, operation will start
before the actual set time. This is to enable the
room temperature reaches the set temperature at
the set time.
• Once the ON-Timer is set, operation will start at the
set time everyday.
• The current time is not displayed when the timers
are set.
• When both timers are used together, the TIMER
mode indicator on the indoor unit remains lit even
when the operation is stopped by the OFF-TIMER.
CONVENIENCE OPERATION
■ Sleep Mode Operation
To obtain a comfortable room temperature while
sleeping:-
• Press 6.
• Sleep mode indicator on the indoor unit will light up.
• To cancel this operation, press once more.
● Sleep Mode Operation Details
• When the room temperature reaches the set
temperature, the airflow volume will change to low
automatically.
• Sleep Mode Operation time is 8 hours.
• When used together with the timer, the timer has a
priority.
Cooling Model
■ Economy Mode Operation
To save electrical power consumption.
Please use this mode when the room has reached
your desired temperature.
• Press 7.
* Economy mode indicator (green) on the indoor unit
will light up.
• Press once more to cancel this operation.
■ Powerful Mode Operation
To obtain the set temperature quickly.
• Press 8.
* Powerful mode indicator (orange) on the indoor
unit will light up.
* Powerful mode will operate for 15 minutes only.
• To cancel this operation, press once more.
●
Economy / Powerful Mode Operation Details
• Economy and Powerful operation cannot be
selected simultaneously.
• The changes of the temperature and airflow volume
are automatic.
• The remote control display remains unchanged.
• If sleep button or operation mode button is pressed,
economy or powerful operation will be cancelled.
• During FAN – Air circulation operation, the powerful
and economy operation are not available.
(cooling model only)
Time
Approx. 0.5°C
increase.
Temperature
Sleep
Operation
button is
pressed.
Sleep shift
operation
starts.
0~1 hour
after approx. 8 hours of sleep shift
operation, it will stop automatically.
Approx.
0.5°C
increase.
• Cooling or Soft Dry
Operation for sleep shift
operation will start to
avoid overcooling.
S
e
t
t
i
n
g
T
e
m
p
e
r
a
t
u
r
e
MODE
SLEEP
ECONOMY
FAN SPEED
AIR SWING
OFF
CANCEL
ON
SET
1
2
3
TIMER
OFF/ON
POWERFUL
3
6
4
1
7
5
2
8
← 1 hour →
Heat Pump Model
Sleep shift
operation starts.
Approx. 3°C
decrease.
• Cooling or Soft Dry
Operation for sleep shift
operation will start to
avoid overcooling.
• Heating operation for
sleep shift operation will
start to avoid overheating.
Sleep
Operation
button is
pressed.
0~1 hour
Approx. 2°C
decrease.
Approx.
0.5°C
increase.
Approx. 0.5°C
increase.
Temperature
S
e
t
t
i
n
g
T
e
m
p
e
r
a
t
u
r
e
Time
← 1 hour →
after approx. 8 hours of sleep shift
operation, it will stop automatically.
Airflow
volume
Super Low
Automatic
Economy Mode
Operation
COOL / DRY
HEAT
(for Heat Pump
model only)
Temperature
0.5°C higher
than set temp.
0.5°C lower
than set temp.
Airflow
volume
Super High
Automatic
Powerful Mode
Operation
COOL / DRY
HEAT
(for Heat Pump
model only)
Temperature
3°C lower
than set temp.
3°C higher
than set temp.
Heat Pump Model
COOL,DRY, – 15 minutes
in advance
HEAT, AUTO– 30 minutes
in advance
Cooling Model
COOL,DRY, – 15 minutes
AUTO in advance
← 1 hour →
35
CS-A18BKP CU-A18BKP5 / CS-A24BKP CU-A24BKP5
Содержание
- Contents 1
- Cs a18bkp cu a18bkp5 cs a24bkp cu a24bkp5 1
- Page page 1
- Room air conditioner 1
- Features 2
- Clock setting 3
- Economy mode operation off on 3
- Functions 3
- Indoor fan speed selection 3
- Operation mode selection 3
- Operation off on 3
- Powerful mode operation off on 3
- Remote control 3
- Room temperature setting 3
- Self illuminating button 3
- Sleep mode operation off on 3
- Time timer setting 3
- Timer operation selection 3
- Timer operation set cancel 3
- Vertical airflow direction control 3
- Airflow direction control 4
- Anti cold draft control 4
- Anti dew formation control 4
- Anti freezing control 4
- Automatic operation button 4
- Economy operation 4
- Hot start control 4
- Indoor fan speed control 4
- Indoor unit 4
- Minutes time save control 4
- Operation indication lamps led 4
- Operation mode 4
- Powerful operation 4
- Random auto restart control 4
- Sleep mode auto control 4
- Time delay safety control 4
- Compressor reverse rotation protection control 5
- Deice control 5
- Outdoor fan operation control 5
- Outdoor unit 5
- Overload protector 5
- Secs forced operation control 5
- Way valve control 5
- Product specifications 6
- 1 cs a18bkp cu a18bkp5 europe 8
- 2 cs a18bkp 2 cu a18bkp5 2 oceania 8
- 3 cs a18bkp 3 cu a18bkp5 3 argentina 8
- 4 cs a18bkp 6 cu a18bkp5 6 turkey 8
- Specifications are subject to change without notice for further improvement 8
- 1 cs a24bkp cu a24bkp5 europe 11
- 2 cs a24bkp 2 cu a24bkp5 2 oceania 11
- 3 cs a24bkp 3 cu a24bkp5 3 argentina 11
- 4 cs a24bkp 6 cu a24bkp5 6 turkey 11
- Specifications are subject to change without notice for further improvement 11
- Cooling mode operation 17
- Operation details 17
- Soft dry mode operation 19
- Heating mode operation 21
- Automatic mode operation 25
- Automatic set temperature 25
- For each operation set temperature will automatically set as shown below 25
- However it can be selected 2 c higher or 2 c lower from standard set temperature by pressing the room temperature setting button 25
- Operation mode will be determine again after 1 hour of operation if the room temperature reaches to set temperature and compressor off time is over 7 minutes 30 seconds continuously 25
- The mode judging temperature and standard setting temperature can be increased by 2 c by open the circuit of jx1 at indoor electronic controller 25
- When the automatic mode operation is selected the indoor fan operates at slo fan speed for 25 seconds to sense intake air temperature and determine the 1st operation mode if indoor intake air temperature is less than 16 c heating mode will immediate operate 25
- Random auto restart control 26
- Sleep mode auto operation 26
- Indoor fan speed control 27
- Airflow direction control 28
- Delay on timer control 29
- Remote control signal receiving sound 29
- Economy mode operation 30
- Powerful mode operation 31
- Soft starter applicable only for australia market 32
- 2 3 6 5 4 33
- Before operating please read the following safety precautions carefully 33
- G do not install remove and reinstall the unit by yourself improper installation will cause leakage electric shock or fire please engage an authorized dealer or specialist for the installation work 33
- G do not install the unit in a potentially explosive atmosphere gas leak near the unit could cause fire 33
- G incorrect operation due to failure to follow instructions will cause harm or damage the seriousness of which is classified as follow 33
- G the instructions to be followed are classified by the following symbols 33
- G this room air conditioner must be earthed improper grounding could cause electric shock g ensure that the drainage piping is connected properly otherwise water will leak out 33
- G to prevent personal injury injury to others and property damage the following instructions must be followed 33
- Operating instructions 33
- Safety precautions 33
- These symbols with a black background denote actions that are compulsory 33
- This sign warns of damage to property 33
- This sign warns of death or serious injury 33
- This sign warns of injury 33
- This symbol with a white background denotes an action that is prohibited 33
- How to operate 34
- Name of each part 34
- Preparation before operation 34
- Convenience operation 35
- Cs a18bkp cu a18bkp5 cs a24bkp cu a24bkp5 35
- Setting the timer 35
- Care and maintenance 36
- Energy saving and operation hints 36
- Helpful information 36
- Cs a18bkp cu a18bkp5 cs a24bkp cu a24bkp5 37
- I abnormal operation 37
- I call the dealer immediately 37
- I normal operation 37
- Troubleshooting 37
- Carry out test running to confirm that no abnormality occurs after the installation then explain to user the operation care and maintenance as stated in instructions please remind the customer to keep the operating instructions for future reference 38
- Electrical work must be installed by a licensed electrician be sure to use the correct rating of the power plug and main circuit for the model to be installed 38
- Installation instructions 38
- Read the following safety precautions carefully before installation 38
- Safety precautions 38
- The caution items stated here must be followed because these important contents are related to safety the meaning of each indication used is as below incorrect installation due to ignoring of the instruction will cause harm or damage and the seriousness is classified by the following indications 38
- The items to be followed are classified by the symbols 38
- How to fix installation plate 41
- Indoor unit 41
- Indoor unit installation 41
- Select the best location refer to select the best location section 41
- To drill a hole in the wall and install a sleeve of piping 41
- Connect the cable to the indoor unit 43
- Connecting the piping 44
- Install the outdoor unit 44
- Outdoor unit 44
- Select the best location refer to select the best location section 44
- A evacuation of the equipment for europe oceania destination 45
- B air purging of the piping and indoor unit 46
- Connect the cable to the outdoor unit 46
- Pipe insulation 47
- 3 way valve 48
- Evacuation of the equipment for europe oceania destination 49
- Evacuation of the installation 49
- Pumping down 50
- Evacuation of re installation 51
- Balance refrigerant of the 3 way valves 52
- Evacuation 53
- Gas charging 54
- Air purging 55
- Air purging of the piping and indoor unit 55
- Pumping down 56
- Re air purging 57
- Balance refrigerant of the 3 way valves 58
- Evacuation 59
- Gas charging 60
- Indoor electronic controllers removal procedures 61
- Servicing information 61
- Cross flow fan indoor and fan motor removal procedures 62
- Refrigeration cycle system 65
- Troubleshooting guide 65
- Carry out the measurements of pressure electric current and temperature fifteen minutes after an operation is started 66
- Diagnosis methods of a malfunction of a compressor and 4 way valve 66
- Relationship between the condition of the air conditioner and pressure and electric current 66
- Exploded view 71
- 1 cs a18bkp cs a24bkp europe 72
- 2 cs a18bkp 2 cs a24bkp 2 oceania 72
- 3 cs a18bkp 3 cs a24bkp 3 argentina 72
- 4 cs a18bkp 6 cs a24bkp 6 turkey 72
- All parts are supplied from macc malaysia vendor code 086 72
- O marked parts are recommended to be kept in stock 72
- Replacement parts list 72
- Exploded view 73
- 1 cu a18bkp5 cu a24bkp5 europe 74
- 2 cu a18bkp5 2 cu a24bkp5 2 oceania 74
- 3 cu a18bkp5 3 cu a24bkp5 3 argentina 74
- 4 cu a18bkp5 6 cu a24bkp5 6 turkey 74
- All parts are supplied from macc malaysia vendor code 086 74
- O marked parts are recommended to be kept in stock 74
- Replacement parts list 74
- Cs a18bk cu a18bk cs a24bk cu a24bk 75
- Electronic circuit diagram 75
- Electronic controller 75
- Schematic diagram 1 3 75
- A52br9020f 76
- A52d0022gb15 76
- A52pst600dr 76
- Cs a18bkp cu a18bkp5 cs a24bkp cu a24bkp5 76
- Schematic diagram 2 3 76
- Cs a18bkp cu a18bkp5 cs a24bkp cu a24bkp5 77
- Electronic control unit 77
- Schematic diagram 3 3 77
- How to use electronic circuit diagram 78
- Timer table 78
Похожие устройства
- Panasonic CS-A24BKP / CU-A24BKP5 Сервис мануал
- Аксион ТВ12 Руководство по эксплуатации
- Panasonic CS-F24DB4E5 Сервис мануал
- Panasonic CS-F28DB4E5 Сервис мануал
- Panasonic CS-XE9DKE Сервис мануал
- Panasonic CU-XE9DKE Сервис мануал
- Panasonic CS-XE12DKE Сервис мануал
- Panasonic CU-XE12DKE Сервис мануал
- Panasonic CS-C9BKPG Сервис мануал
- Panasonic CS-C7BKPG Сервис мануал
- Panasonic CS-C12BKPG Сервис мануал
- Panasonic CU-2C14BKP5G Сервис мануал
- Аксион РС11 Инструкция к приложению
- Аксион РС11 Руководство по эксплуатации
- Аксион Р36 Руководство по эксплуатации
- Panasonic CU-3C20BKP5G Сервис мануал
- Аксион Р37 Руководство по эксплуатации
- Panasonic CU-2C19BKP5G Сервис мануал
- Аксион ВС 11.02 Руководство по эксплуатации
- Panasonic WH-MXF09D3E8 Сервис мануал