Karcher K 3.00 S [14/224] Danger

Karcher K 3.00 S [14/224] Danger
- 4
Special accessories expand the possibilities
of using your appliance. Please contact your
KÄRCHER dealer for further information.
Illustration
Mount loose parts delivered with appliance
prior to start-up.
Illustration
Push the high pressure hose into the trig-
ger gun until it locks audibly.
Note: Make sure the connection nipple is
aligned correctly.
Check the secure connection by pulling
on the high-pressure hose.
Illustration
Fasten the quick coupling for the high
pressure hose to the high pressure con-
nection.
Illustration
Screw the coupling element (supplied) to
the water connection on the appliance.
According to the applicable regula-
tions, the appliance must never be
used on the drinking water supply
without a system separator. Use a
suitable system separator manufactured by
KÄRCHER; or, as an alternative, a system
separator as per EN 12729 Type BA. Water
flowing through a system separator is consid-
ered non-drinkable.
Caution
Always connect the system separator to the
water supply, never directly to the appliance!
Note: Impurities in the water can damage the
high-pressure pump and accessories. For
protection, the use of the KÄRCHER water fil-
ter (optional accessory, order no. 4.730-059)
is recommended.
Observe regulations of water supplier.
For connection values, see type plate/techni-
cal data.
Use a fibre-reinforced water hose (not in-
cluded) with a standard coupling. (Mini-
mum diameter 1/2 inch (13 mm),
minimum length 7.5 m).
Push the water supply hose onto the cou-
pling unit, then connect it to the water sup-
ply.
This high-pressure cleaner is suited to work
with the KÄRCHER suction hose with back-
flow valve (Optional accessory, order no.
4.440-238) to draw in surface water, e.g. from
water butts or ponds (see specifications for
max. suction height).
Fill the KÄRCHER suction hose with
backflow valve with water, screw to water
supply and hang into the water butt.
Separate the high pressure hose from the
high pressure connection of the appli-
ance.
Switch the appliance on (I/ON) for a max.
of 2 minutes and wait until the water exits
the high-pressure connection without bub-
bles.
Turn off the appliance "0/OFF".
Caution
Dry runs lasting longer than two minutes lead
to damages to the high pressure pump. If the
appliance does not build up pressure within
two minutes, switch it off and proceed as in-
structed in the Chapter "Troubleshooting".
Push the high pressure hose into the
quick coupling until it locks audibly.
Push the spray lance into the trigger gun
and fasten it by turning it through 90°.
Completely open the water tap.
Insert the mains plug into the socket.
Turn on the appliance “I/ON”.
Danger
The trigger gun is subjected to a recoil force
when the water jet is discharged. Make sure
that you have a firm footing and are also hold-
ing the trigger gun and spray lance firmly.
Caution
Prior to cleaning, make sure that the high
pressure is placed safely on level ground.
Wear protective goggles and protective cloth-
ing during the cleaning process.
Unlock the lever on the trigger gun.
Special accessories
Before Startup
Water supply
Water supply from mains
Drawing in water from open reservoirs
Start up
Operation
14 EN