Field#
Field Type
Data Description
Format
Binary
Offset
9
Utc hour
UTC hour (0-23)
Uchar
H+34
10
Utc min
UTC minute (0-59)
Uchar
H+35
11
Utcms
UTC millisecond (0-60999)
Ulong
H+36
12
Utc status
UTC status: 0 = Invalid, 1 = Valid, 2 = Warning
Enum
H+40
13
CRC
32-bit CRC
Hex
H+44
Table 48.Clock Model Status
VALUE
CLOCK STATUS
DESCRIPTION
0
VALID
The clock model is valid
1
CONVERGING
The clock model is near validity
2
ITERATING
The clock model is iterating towards validity
3
INVALID
The clock model is not valid
4
ERROR
Clock model error
4.3 INTERNATIONAL STANDARD MESSAGES
4.3.1 NMEA sentences
4.3.1.1 Standard NMEA sentences
4.3.1.1.1 GPGGA GNSS Fix Data
Description
This message is a standard NMEA log, but a little different from the standard one in position
precision. The position precision of this log is the same as GPGGARTK, in order to be used in
greater conditions. The header of GPGGA is always “GP regardless if other GNSS information
involved in solution computation.
Message ID
218
Recommended Input
log gpgga ontime 1
Supported Format
ASCII

Содержание