Orient K706 [229/244] Rtcm 3 x

Orient ОС-201 [229/244] Rtcm 3 x
COMNAV OEM BOARD REFERENCE MANUAL
Chapter 5. Frequently-Used Operations
ComNav Technology Ltd.
210
CNT-OEM-RM001, Rev 1.8
Command1: LOG COM1 RTCM3B ONTIME 5
Message 3 outputted from COM1 every 5 second
Command2: LOG COM1 RTCM1819B ONTIME 1
Message 1819 outputted from COM1 every 1 second
Command3: FIX AUTO
Fix reference station coordinates in auto mode
Command3: FIX POSITION 30.0 150.0 50
Fix reference station coordinates in manual mode
Command4: SAVECONFIG
Save configurations in flash
Description
Just like above example, the way to set up a RTCM2 base station is as below.
LOG TYPE
SYNCH
NOTE
Recommended
Input
interfacemode com2 none rtcm
fix position 30.123 121.456 50.789
log com2 rtcm3b ontime 10
log com2 rtcm1819b ontime 1
configure port
Identify station position
Set position message
Set observables message
5.3.2 RTCM 3.X
Description
Because BD2 differential messages are not involved in RTCMV3 official documents, we define
message: 1104 to encode BD2 observations currently.
BD2 differential data not defined in RTCMV3 official documents, so message 1104
may be updated or disabled in the future.

Содержание