Orient K706 [51/244] Ppscontrolcontrol the pps output style

Orient K706 [51/244] Ppscontrolcontrol the pps output style
COMNAV OEM BOARD REFERENCE MANUAL
Chapter 3. Compatible Commands
ComNav Technology Ltd.
32
CNT-OEM-RM001, Rev 1.8
3.2.20 PPSCONTROL Control the PPS output style
Format
PPSCONTROL <switch><polarity><period><pulse-width>
Description
This command can be used to set the polarity, period and pulse-width of PPS output. The PPS
can’t be disabled and the update rate can be up to 10 Hz.
Parameters
switch ‘enable’ or ‘disable’, the switch should be set to ‘enable’, and ‘disable’ is not
allowed.
polarity ‘positive’ and ‘negative’, if ‘positive’, it should be a high level pulse, a low level
pulse correspond to a ‘negative’ mode.
period in seconds, period’ can’t be configured, it is constantly 1 second temporary.
pulse-width in microseconds, pulse-width should be less than half of period.
Example
PPSCONTROL ENABLE POSITIVE 1 1000
3.2.21 PPMADJUST Adjust PPM or not
Format
PPMADJUST <status>
Description
This command is used to decide whether adjust the PPM or not.
Parameters
status ON (adjust) / OFF (don’t adjust)
Example
PPMADJUST ON //Adjust PPM.
PPMADJUST OFF //Not adjust PPM.