Graco REACTOR 2 H-30 PHH132 Техническая документация онлайн [24/110] 680018

Graco REACTOR 2 H-30 PHH132 Техническая документация онлайн [24/110] 680018
Troubleshooting
Error Error
Error
Location Location
Location
Type Type
Type
Description Description
Description
Cause Cause
Cause
Solution Solution
Solution
System
pressurizedbefore
allowingheatto
reachsetpoint
Pressureinthehoseand
pumpswillincreaseasthe
systemheatsup.Turnon
heatandallowallzones
toreachthetemperature
setpointbeforeturningon
thepumps.
Badpressure
transducer
VerifytheADMpressure
readingandtheanalog
gaugesatthemanifold.
P4BX
HCM
HighPressureB
H-XP2orH-XP3
systemcon󰘰gured
asH-30,H-40,or
H-50
Alarmlevelislowerfor
H-30,H-40andH-50than
forH-XP2andH-XP3..
EnsuredialonHCMisset
toposition"3"forH-XP2or
“4”forH-XP3.
Thermalexpansion
isoccurring
betweenthedrum
andReactorinlet
Conditionthedrummaterial
totheambienttemperature
oftheReactor.
P4FAADMAPumpInletLeak
DamagedISO
pumpinletballor
seat
ReplacetheISOpumpinlet
ballandseat.
Thermalexpansion
isoccurring
betweenthedrum
andReactorinlet
Conditionthedrummaterial
totheambienttemperature
oftheReactor.
P4FBADMBPumpInletLeak
Damagedresin
pumpinletballor
seat
Replacetheresinpump
inletballandseat.
Loose/bad
connection
Checktoensurethe
pressuretransduceris
properlyinstalledand
allwiresareproperly
connected.
P6AX
HCM
PressureSensor
ErrorA
Badsensor
Checkiftheerrorfollows
thetransducer.Disconnect
transducercablesfrom
theHCM(connectors6
and7).ReverseAandB
connectionsandcheckif
theerrorsfollows.Ifthe
errorfollowsthetransducer,
replacethepressure
transducer.
24
334946H

Содержание

Скачать