Troubleshooting
Error Error
Error
Location Location
Location
Type Type
Type
Description Description
Description
Cause Cause
Cause
Solution Solution
Solution
Loose/bad
connection
Checktoensurethe
pressuretransduceris
properlyinstalledand
allwiresareproperly
connected.
P6BX
HCMPressureSensor
ErrorB
Badsensor
Checkiftheerrorfollows
thetransducer.Disconnect
transducercablesfrom
theHCM(connectors6
and7).ReverseAandB
connectionsandcheckif
theerrorsfollows.Ifthe
errorfollowsthetransducer,
replacethepressure
transducer.
Inletsensorsnot
installed
Ifinletsensorsarenot
installed,inletsensors
shouldbedisabledonthe
SystemSetupscreen.
Loose/bad
connection
Checktoensureinlet
sensorisproperlyinstalled
andallwiresareproperly
connected.
P6FA
HCM
PressureSensor
ErrorInletA
Badsensor
Checkiftheerrorfollows
theinletsensor.Disconnect
inletsensorcablesfrom
theHCM(connectors8
and9).ReverseAandB
connectionsandcheckif
theerrorsfollows.Ifthe
errorfollowsthesensor,
replacetheinletsensor.
Inletsensorsnot
installed
Ifinletsensorsarenot
installed,inletsensors
shouldbedisabledonthe
SystemSetupscreen.
Loose/bad
connection
Checktoensureinlet
sensorisproperlyinstalled
andallwiresareproperly
connected.
P6FB
HCM
PressureSensor
ErrorInletB
Badsensor
Checkiftheerrorfollows
theinletsensor.Disconnect
inletsensorcablesfrom
theHCM(connectors8
and9).ReverseAandB
connectionsandcheckif
theerrorsfollows.Ifthe
errorfollowsthesensor,
replacetheinletsensor.
334946H 25