Shimadzu UW-2200H [129/129] 56829 21f nov 2010

Shimadzu UW-2200H [129/129] 56829 21f nov 2010
Pressing [CAL] key moves to the next menu in the same hierarchy. ( in menu map)
Pressing [O/T] key moves to the menu of one hierarchy down. ( in menu map)
When no menu exists in the menu of one hierarchy down, it is fixed.
Pressing [POWER] key returns to the menu of one hierarchy up. ( direction in menu map)
(The mass display)
CAL Execution menu
Executes calibration.
WindowsDirect Setting
mark blinking
Menu Group 1
([CAL] key three times from mass-display)
Sets type of calibration to execute
blinking Sets I-CAL. (Adjusting sensitivity
with the built-in weight) # 1
blinking Sets I-TEST. (Testing sensitivity
with the built-in weight) 2
blinking Sets E-CAL. (Adjusting sensitivity
with the external we
ight) #
*
3
blinking Sets E-TEST. (Testing sensitivity
with the external we
ight)
*
4
blinking
Fully-automatic calibration PSC On/Off
Sets PSC ON 5
Sets PSC OFF # 6
blinking
Fully-automatic calibration
Clock-CAL settings
time 1 7
time 2 8
time 3 9
blinking
Executes calibration of the built-in
calibration weight
*
10
B
Analog display blinking
Menu Group 2
Menu Group 3
([CAL] key four times from mass-display)
blinking
Full Scale mode #
11
blinking
Taget mode
12
Target value
13
Limit value
14
blinking
Checkweighing Display 1
Checkweighing Display 2
15
Upper threshold
16
Lower threshold
17
blinking 18
Upper threshold 19
Lower threshold 20
blinking
No analog display
21
blinking
([CAL] key five times from mass-display)
blinking
Stability and Response
Timing of Stability Mark
Auto #
22
Pouring
23
Standard
24
21a
21b
21c
Anti-vibration
25
Anti-wind
26
blinking
Stability detection band
1 count #
27
2 counts
28
4 counts
29
8 counts
30
16 counts
*
31
32 counts
*
32
64 counts
*
33
blinking
Tracking
ON #
34
OFF
35
and blinking
Pretaring
*
Whole lighting at start
36
blinking
holds
37
Does not hold #.
38
blinking
Taring/Printing at Stability
*
Immediately
#
*
39
Waiting for stabilization
*
40
fast
standard #
delayed
blinking
blinking
Menu Group 4 ([CAL] key six times from gram-display)
mark blinking
Auto Zero
On
*
On
41
mark blinking
Auto Print
Loading 42
Loading and unloading 43
Loading and zero 44
Loading, unloading, and zero
45
Continuous
*
46
Stability with GO 47
blinking
Zero Range
48
blinking
Peak Holding On
*
49
blinking
Interval Timer
*
Time interval
*
50
mark blinking
Add-on Mode
Formulation Mode
52
51
mark blinking
Animal Weighing
On
*
On
On
53
and blinking
A
blinking
Menu Group 5 ([CAL] key seven times from mass-display)
kg kg (kg) 54
mg mg (mg
)
*
55
%#
pcs Number # (PC) 5
5
7
ct Carat (CT) 58
mom Momme (MO
)
*
59
d Solid Specific gravity measurement 60
d Liquid density measurement 61
Lb
Pound
*
61a
Oz
Ounce
*
61b
Ozt Troy
Ounce
*
61c
Hong Kong's tael
*
61d
Singapore tael
*
61e
Taiw
anese tael
*
61f
Malaysia tael
*
61g
Chinese tael
*
61h
61i
GN
Grain
*
61j
mM
esgal
*
61k
b
baats
*
61l
tt
ara
*
61m
SettheMultiplierforUserunit
*
(US) 62
During measurement,
these items are
distinguished by the
position of the symbol
dwt pennyweigh
*
6
(%)
A
Menu Group 6
blinking
([CAL] key eight times from mass-display).
blinking
blinking
Date setting
63
64
blinking
Display during standby setting
Time 65
Date 66
No display #
##
67
63a
63b
63c
blinking
Report and control setting
CAL report output
On 68
Off # 69
Balance ID
70
PCAL Passw
ord
*
71
blinking
blinking
Menu reset to default
Decimal point output
72
Date output style
Date setting
Period( . ) #
Comma( , )
Time setting
72a
72b
B
Menu Group 7
mark blinking
([CAL] key nine times from gram-display)
blinking
Handshaking
Not provided 73
Software 74
Hardware 75
Timer # 76
blinking
Data Format
EB type # 77
Old EB type 78
PR type 79
IPS type 80
blinking
Baud Rate (Bits/sec)
300 bps 81
600 bps 82
1200 bps # 83
2400 bps 84
4800 bps 85
9600 bps 86
19200 bps 87
38400 bps 88
blinking
Parity & bit length
None (8 bits) # 89
Odd (7 bits) 90
Even (7 bits) 91
blinking
Stop bit
1 bit # 92
2 bits 93
blinking
Delimiter
CR # 94
LF 95
CR+LF 96
WindowsDirect down 97
WindowsDirect right 98
*
No. :
Menu item number
# :
Default settings. Settings are initialized to default by “Menu reset”.
# # :
Default settings. Settings are not initialized to default by “Menu reset”.
:
These units cannot be selected in some countries due to legal restriction.
*
#
Menu Map
Cannot enter the menu?
“LoCKEd” is displayed and returns to mass display when menu access is attempted? J Menu is locked.
How to remove Menu Lock
Press [POWER] (It goes STAND-BY) J Disconnect power cable J Connect power cable again (Dis-
plays proceed and it stands at “oFF”) J Press [CAL] (Displays proceed: “rELEASE” then “oFF”) J
Press [POWER] (It returns to the mass display) (Refer to 7.5.3 for detail.)
*Not applicable to a verified balance as a legal measuring instrument in the EU
Refer to main manual 7.3 for menu item selection.
Important Note on Menu Item Selection!
Even the desired menu item is reached and displayed, it is not yet set
unless Stability mark ( ) is illuminated with it. Do not fail to press
[O/T] key to put Stability mark before returning to the mass display.
321-56829-21F
Nov. 2010

Содержание

Скачать