Method Of Measurement
This product employs the oscillometric method for measurement of blood pressure and pulse rate.
The cuff is connected to the main unit and wrapped around the arm. Circuits within the cuff sense
the small oscillations in pressure against the cuff produced by the expansion and contraction of the
arteries in the arm in response to each heart beat. The amplitude of each pressure waves is measured,
converted to millimeters of mercury, and displayed on the LCD as a digital value.
Used new NISSEI Technologies
Fuzzy Infl ation This product employs FUZZY infl ation to ease stress on wrist during
cuff infl ation. By detecting pulse signals while infl ating, this product is able to determine
the suffi cient pressure for each measurement.
Arrhythmia Indicator – displays when the pulse rhythm detected during measurement
was irregular. Pulse rhythm can be disturbed from talking, moving or arrhythmias.
Touch Control – touch-sensor operation.
Body Motion Indicator – blood pressure value taken while moving cannot be said to be
the correct value because body movement can aff ect blood pressure.
Cuff Symbol – displays whether the cuff is applied properly or not.
Reliability Symbol displays when the measurement is supposedly made in good
condition.
Pulse Pressure Display – calculates and displays pulse pressure. Pulse pressure is
value subtract diastolic value from systolic value and therefore pulse pressure tends to
increase with age.
ATTENTION! Do not use cuff s other than the original cuff included with this product.
COMPLETE SET
1. Main body – 1 pcs.
2. Cuff – 1 pcs.
3. Battery – 4 pcs.
4. AC Adapter – 1 pcs.
5. Carrying bag – 1 pcs.
6. Instruction manual – 1 pcs.
7. Warranty card – 1 pcs.
8. Packing – 1 pcs.
TIPS ON TAKING YOUR BLOOD PRESSURE
1 Do not use this product without consultation with your doctor if you are under dialysis therapy
or on anticoagulants, antiplatelets or steroids. Use of this instrument under such conditions could
cause internal bleeding.
2
Use of this product in areas near mobile phones, microwave ovens or other devices with strong
electromagnetic fi eld may cause malfunctions.
3 For correct measurement it is necessary to know that ARTERIAL BLOOD PRESSURE SUBJECTED TO
SHARP FLUCTUATIONS IN SHORT GAP OF TIME. The level of the arterial blood pressure depends on many
factors. Usually level of arterial blood pressure is lower in summer and higher in winter. Arterial blood