OMNITRONIC PAP-120 PA Amplifier Руководство по эксплуатации онлайн [16/25] 757815
![OMNITRONIC PAP-120 PA Amplifier Руководство по эксплуатации онлайн [16/25] 757815](/views2/1989530/page16/bg10.png)
00041813.DOC, Version 1.2
16/25
Please make sure that there are no obvious transport damages. Should you notice any damages on the A/C
connection cable or on the casing, do not take the device into operation and immediately consult your local
dealer.
This device falls under protection-class I. The power plug must only be plugged into a protection class I
outlet. The voltage and frequency must exactly be the same as stated on the device. Wrong voltages or
power outlets can lead to the destruction of the device and to mortal electrical shock.
Always plug in the power plug least. The power plug must always be inserted without force. Make sure that
the plug is tightly connected with the outlet.
Never let the power cord come into contact with other cables! Handle the power cord and all connections
with the mains with particular caution! Never touch them with wet hands, as this could lead to mortal
electrical shock.
Never modify, bend, strain mechanically, put pressure on, pull or heat up the power cord. Never operate next
to sources of heat or cold. Disregard can lead to power cord damages, fire or mortal electrical shock.
The cable insert or the female part in the device must never be strained. There must always be sufficient
cable to the device. Otherwise, the cable may be damaged which may lead to mortal damage.
Make sure that the power cord is never crimped or damaged by sharp edges. Check the device and the
power cord from time to time.
If extension cords are used, make sure that the core diameter is sufficient for the required power
consumption of the device. All warnings concerning the power cords are also valid for possible extension
cords.
Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the power
cord by the plug. Never pull out the plug by tugging the power-cord. Otherwise, the cable or plug can be
damaged leading to mortal electrical shock. If the power plug or the power switch is not accessible, the
device must be disconnected via the mains.
If the power plug or the device is dusty, the device must be taken out of operation, disconnected and then be
cleaned with a dry cloth. Dust can reduce the insulation which may lead to mortal electrical shock. More
severe dirt in and at the device should only be removed by a specialist.
There must never enter any liquid into power outlets, extension cords or any holes in the housing of the
device. If you suppose that also a minimal amount of liquid may have entered the device, it must immediately
be disconnected. This is also valid, if the device was exposed to high humidity. Also if the device is still
running, the device must be checked by a specialist if the liquid has reduced any insulation. Reduced
insulation can cause mortal electrical shock.
There must never be any objects entering into the device. This is especially valid for metal parts. If any metal
parts like staples or coarse metal chips enter into the device, the device must be taken out of operation and
disconnected immediately. Malfunction or short-circuits caused by metal parts may cause mortal injuries.
The device and all connections have to be lightning protected.
Never install the amplifier next to highly sensitive devices like pre-amplifiers or tape-decks, as the strong
magnetic field of the amplifier can produce hum in these devices. The magnetic field is strongest directly
above or below the amplifier. If a rack is used, the amplifier should be installed at the bottom and the highly
sensitive devices at the top.
Only connect the device when the power switch is off.
Never connect the inputs or outputs to any power source (batteries, etc.)
Never connect output to output.
Before the device is switched on all faders and volume controls have to be set to "0" or "min" position.
Содержание
- Bedienungsanleitung user s manual 1
- Pa amplifier 1
- Pap series 1
- Das neueste update dieser bedienungsanleitung finden sie im internet unter 3
- Inhaltsverzeichnis table of contents 3
- Www omnitronic com 3
- You can find the latest update of this user manual in the internet under 3
- Achtung 4
- Bedienungsanleitung 4
- Einführung 4
- Ela verstärker 4
- Sicherheitshinweise 4
- Kleine hörkunde 6
- Rechtliche hinweise 6
- Bestimmungsgemässe verwendung 7
- Features 8
- Geräteübeschreibung 8
- Bedienelemente und anschlüsse 9
- Anschlüsse 10
- Eingänge 10
- Installation 10
- Ausgänge 11
- Belegung klinkenstecker 11
- Doc version 1 11 25 11
- Es können entweder ela lautsprecher mit 70 v bzw 100 v audioübertrager oder 4 16 ω lautsprecher bzw lautsprechergruppen mit einer gesamtimpedanz von mindestens 16 ω angeschlossen werden schließen sie ela lautsprecher and die klemmen com und 100 v bzw 70 v an schließen sie niederohmige lautsprecher and die klemmen com und 4 16 ω achten sie beim anschluss auf die richtige polarität plus und minusanschlüsse die klemme com ist immer der minuspol 11
- Anschluss ans netz 12
- Bedienung 12
- Durchschleifausgang 12
- Schutzschaltungen 12
- Lebensgefahr 13
- Problembehebung 13
- Reinigung und wartung 13
- Sicherungswechsel 13
- Technische daten 14
- Caution 15
- Introduction 15
- Pa amplifier 15
- Safety instructions 15
- User manual 15
- Information on hearing loss 17
- Legal instructions 17
- Operating determinations 18
- Description 19
- Features 19
- Operating elements and connections 20
- Connections 21
- Inputs 21
- Installation 21
- Doc version 1 22 25 22
- Either pa speakers with 70 v or 100 v audio transformer or 4 16 ω speakers or speaker groups with a total impedance of at least 16 ω can be connected connect pa speakers to the terminals com and 100 v or 70 v connect low impedance speakers to the terminals com and 4 16 ω when connecting observe the correct polarity positive and negative connections the terminal com is always the negative pole 22
- Occupation jack plug 22
- Outputs 22
- Connection with the mains 23
- Feed through output 23
- Operation 23
- Protective circuits 23
- Cleaning and maintenance 24
- Danger to life 24
- Problem chart 24
- Replacing the fuse 24
- Technical specifications 25
Похожие устройства
- MXL AC-404-Z Руководство по эксплуатации
- MXL 440 Руководство по эксплуатации
- MOTU 828x Руководство по эксплуатации
- EUROSOUND EST-115A Руководство по эксплуатации
- EBS ReTracer Delay Workstation Руководство по эксплуатации
- EBS Micro Bass 3 Руководство по эксплуатации
- Volta US-102 (600-636 МГц) Руководство по эксплуатации
- Volta US-1H (629.40) Руководство по эксплуатации
- Volta US-101 (600-636 МГц) Руководство по эксплуатации
- VISATON WB 16 Руководство по эксплуатации
- VISATON WB 13 Руководство по эксплуатации
- Sennheiser Urbanite Руководство по эксплуатации
- VERSE SUB 215 MKII Руководство по эксплуатации
- VERSE SUB 10 MKII Руководство по эксплуатации
- VERSE DSUB 15 Руководство по эксплуатации
- VERSE DSIDER M12 Руководство по эксплуатации
- TC HELICON Play Electric Руководство по эксплуатации
- STEINBERG USB eLicenser Руководство по эксплуатации
- STUDIOLOGIC SL88 Studio Руководство по эксплуатации
- STEINBERG UR22C Руководство по эксплуатации