Overview on the different noise levels
10 dB Heartbeat
80 dB Heavy traffic or telephone ringing
20 - 30 dB Whisper 90 dB Pneumatic drill
40 dB Average home 100 dB Power mower
50 dB Light traffic 120 dB Boom box in car
60 dB Normal conversation 130 dB Pain level
70 dB Vacuum cleaner 140 dB Jet plane 30 meters overhead
It is important to know that doubling the power increases the noise level by 3 dB. The human hearing does
only recognizes a doubling of the sound level when the noise level is increased by 10 dB. Damaging the
hearing does not depend on the sound level but on the noise level and starts way before the pain level.
Many people deceive themselves by thinking that noise is something they can get accustomed to. It is
possible that a positive opinion of a certain noise can reduce the physiological reaction, but the slow impacts
on the inner hearing must not be neglected: over stimulation and continuous elimination of the Cortic organ's
hair cells.
The reason why some people have got accustomed to a certain noise level and are no longer disturbed is
that they have already suffered a hearing damage. This damage make the insensitive to those frequencies
forming the loudest part of the noise. Getting accustomed to noise does not mean anything other than trying
to get along with the hearing loss in everyday life. The hearing loss itself cannot be healed, it can only be
compensated by hearing aids.
Subjectively, the hearing loss feels like dampened ears. This effect weakens with the time, but a loss in
hearing sensitivity often remains.
In order to relax the hearing sufficiently, the noise level should not exceed 70 dB(A) for 10 hours. Higher
noise levels during this relaxing period can prevent the relaxation and promote a permanent hearing damage
(Tinitus) or hearing loss.
Therefore: Whoever wants to maintain his hearing should use hearing protectors!
4. OPERATING DETERMINATIONS
This device is a PA amplifier for amplifying audio signals. This product is allowed to be operated with an
alternating current of 230 V, 50 Hz and was designed for indoor use only.
This device is designed for mobile use and for permanent installations.
By operating amplifying systems, you can produce excessive sound pressure levels that may lead to
permanent hearing loss. Please refer to the explanations under "Legal instructions".
Please note: operating an amplification system in public or industrial areas, a series of safety instructions
have to be followed that this manual can only give in part. The operator must therefore inform himself on the
current safety instructions and consider them.
Do not shake the device. Avoid brute force when installing or operating the device.
When choosing the installation-spot, please make sure that the device is not exposed to extreme heat,
moisture or dust. There should not be any cables lying around. You endanger your own and the safety of
others!
This device must never be operated or stockpiled in surroundings where splash water, rain, moisture or fog
may harm the device. Moisture or very high humidity can reduce the insulation and lead to mortal electrical
shocks. When using smoke machines, make sure that the device is never exposed to the direct smoke jet
and is installed in a distance of 0.5 meters between smoke machine and device.
The ambient temperature must always be between -5° C and +45° C. Keep away from direct insulation
(particularly in cars) and heaters.
The relative humidity must not exceed 50 % with an ambient temperature of 45° C.
Содержание
- Bedienungsanleitung user s manual 1
- Pa amplifier 1
- Pap series 1
- Das neueste update dieser bedienungsanleitung finden sie im internet unter 3
- Inhaltsverzeichnis table of contents 3
- Www omnitronic com 3
- You can find the latest update of this user manual in the internet under 3
- Achtung 4
- Bedienungsanleitung 4
- Einführung 4
- Ela verstärker 4
- Sicherheitshinweise 4
- Kleine hörkunde 6
- Rechtliche hinweise 6
- Bestimmungsgemässe verwendung 7
- Features 8
- Geräteübeschreibung 8
- Bedienelemente und anschlüsse 9
- Anschlüsse 10
- Eingänge 10
- Installation 10
- Ausgänge 11
- Belegung klinkenstecker 11
- Doc version 1 11 25 11
- Es können entweder ela lautsprecher mit 70 v bzw 100 v audioübertrager oder 4 16 ω lautsprecher bzw lautsprechergruppen mit einer gesamtimpedanz von mindestens 16 ω angeschlossen werden schließen sie ela lautsprecher and die klemmen com und 100 v bzw 70 v an schließen sie niederohmige lautsprecher and die klemmen com und 4 16 ω achten sie beim anschluss auf die richtige polarität plus und minusanschlüsse die klemme com ist immer der minuspol 11
- Anschluss ans netz 12
- Bedienung 12
- Durchschleifausgang 12
- Schutzschaltungen 12
- Lebensgefahr 13
- Problembehebung 13
- Reinigung und wartung 13
- Sicherungswechsel 13
- Technische daten 14
- Caution 15
- Introduction 15
- Pa amplifier 15
- Safety instructions 15
- User manual 15
- Information on hearing loss 17
- Legal instructions 17
- Operating determinations 18
- Description 19
- Features 19
- Operating elements and connections 20
- Connections 21
- Inputs 21
- Installation 21
- Doc version 1 22 25 22
- Either pa speakers with 70 v or 100 v audio transformer or 4 16 ω speakers or speaker groups with a total impedance of at least 16 ω can be connected connect pa speakers to the terminals com and 100 v or 70 v connect low impedance speakers to the terminals com and 4 16 ω when connecting observe the correct polarity positive and negative connections the terminal com is always the negative pole 22
- Occupation jack plug 22
- Outputs 22
- Connection with the mains 23
- Feed through output 23
- Operation 23
- Protective circuits 23
- Cleaning and maintenance 24
- Danger to life 24
- Problem chart 24
- Replacing the fuse 24
- Technical specifications 25
Похожие устройства
- MXL AC-404-Z Руководство по эксплуатации
- MXL 440 Руководство по эксплуатации
- MOTU 828x Руководство по эксплуатации
- EUROSOUND EST-115A Руководство по эксплуатации
- EBS ReTracer Delay Workstation Руководство по эксплуатации
- EBS Micro Bass 3 Руководство по эксплуатации
- Volta US-102 (600-636 МГц) Руководство по эксплуатации
- Volta US-1H (629.40) Руководство по эксплуатации
- Volta US-101 (600-636 МГц) Руководство по эксплуатации
- VISATON WB 16 Руководство по эксплуатации
- VISATON WB 13 Руководство по эксплуатации
- Sennheiser Urbanite Руководство по эксплуатации
- VERSE SUB 215 MKII Руководство по эксплуатации
- VERSE SUB 10 MKII Руководство по эксплуатации
- VERSE DSUB 15 Руководство по эксплуатации
- VERSE DSIDER M12 Руководство по эксплуатации
- TC HELICON Play Electric Руководство по эксплуатации
- STEINBERG USB eLicenser Руководство по эксплуатации
- STUDIOLOGIC SL88 Studio Руководство по эксплуатации
- STEINBERG UR22C Руководство по эксплуатации