Karcher RBS 6014 [19/88] Technical specifications

Karcher RBS 6014 [19/88] Technical specifications
- 8
Danger
Risk of electric shock!
Work on electrical plant only to be carried
out by qualified electricians.
Switch the plant to voltage-free with all
work, in this case switch the plant at the
main switch to “0”and secure against it
switching on again.
Who may remedy faults?
Operator
Work designated with the sign “Operator”
may only be carried out by persons who
have been instructed in the safe operation
and maintenance on the wash plant
Electricians
Persons with a professional training in the
electro-technical area.
Customer Service
Work designated with the sign “Customer
Service” may only be done by the fitters of
Kärcher Customer Service or fitters who
have been authorised by Kärcher.
Danger
Risk of electric shock.
Switch on the plant voltage-free, in addition
switch on the main switch to “0” and secure
it against being switched on again.
Risk of eye injuries from parts flying off or
dirt. Keep clear off rotating brushes. Gog-
gles must be worn during maintenance
work.
Troubleshooting
Faults
Fault Possible cause Remedy of whom
Plant is not running No power supply Check electrical mains. Qualified
electrician
Fuse defective. Remove the cause.
Replace the fuse.
Protective motor switch was triggered. Check the current pickup.
Brush is does not reach re-
quired speed
Bearings stuck. Check the brush bearing. Operator
Dosing pump does not
suck in spite of ventilation
and maximum dosing vol-
ume
Residue on valve seats, stuck valves. Flush the suction hoses and valves. Operator
Dosing pump sucks air Connection of suction valve or pressure
valve leaks.
Check the valves and suction hoses for leaks. Operator
Pump head not tightened. Tighten the pump head screws. Operator
Pumps of the dosing pump
leak
Pump head not tightened.
Membrane spring broken.
Tighten the pump head screws.
Replace the membrane.
Operator
Dosing pump does not op-
erate even though the indi-
cator lamp is lit.
No power supply Check power supply and ensure proper sup-
ply.
Operator
Fuse defective. Replace the fuse. Operator
PCB defective. Replace PCB. Qualified
electrician
Spray pattern of the noz-
zles irregular.
Nozzles are blocked. Clean the nozzles. Operator
Technical specifications
Plant dimensions
RBS 6012 RBS 6013 RBS 6014
System height mm 3180 4090 4370
Washing height mm 3645 3925 4205
System width mm 1700
Weight kg 234 237 240
Washing station requirements mm Vehicle length +4000
Vehicle width + 4000
Water flow pressure MPa (bar) 0,3...0,6 (3...6)
Water connection Inch 3/4
Water consumption, approx. I/min 80
Max. water temperature °C 30
Power Input kW 1,1
Type of protection IP54 IP45
Ambient temperature °C +3...+50
Humidity, max. % 70
Sound pressure level L
pA
dB(A) 65
Uncertainty K
pA
dB(A) 4
Vibration total value on arms m/s
2
<2,5
Uncertainty K m/s
2
0,1
19EN