4. TROUBLESHOOTING
4) When the DEF-Sensor is defective
ERROR CODE
MAIN PCB Connector
CN30 is inserted properly?
F-DEF Sensor is
normal?
Voltage between MAIN PCB
Connector CN30-"4"(RED) and "7"(GRY)
is normal?
Input Voltage at IC10
MICOM Pin #24 is normal?
Start
PCB and Temp Sensor are normal.
Check the connector contact.
Connector contact defect /
Reconnect
Replace Temp Sensor
Check the wire connection
Check Soldering Defect & Short
No
No
No NO (0.6V > Value or Value > 4.6V)
No
Yes
Yes
Yes
Yes
Sensor MICOM/Connector #
F DEF
Between Connector CN30"-
"4"(RED) and CN30-"7"(GRY)
Voltage : Between 4.6V ~ 0.6V
** Sensor Resistance Reading Location **
F-DEF : Between CN30 #4 and #7
** 0Ω : Short / ∞Ω : Open
Voltage at IC10 MICOM #
24 is the same as the value
between CN30-"4"(RED) and
CN30-"7"(GRY).
Refer to Circuit Diagram
DATA1. Temp Table

Содержание