RME OCTAMIC XTC Руководство по эксплуатации онлайн [17/62] 776279

RME OCTAMIC XTC Руководство по эксплуатации онлайн [17/62] 776279
User’s Guide OctaMic XTC © RME
17
PAD (Channels 1-4)
Channels 1 to 4 have an optional attenuator directly at the input stage. PAD reduces the signal
level by -20 dB, avoiding overload when feeding high-level line signals. XLR and TRS socket
are active at the same time, no switching between them is required. An active PAD is signaled
by an LED on the front panel.
Instrument (Channels 5-8)
Channels 5 to 8 have a high impedance instrument input. This function switches from the XLR
to the TRS socket. The current state is signaled by an LED on the front panel.
Phase Invert
Phase changes the polarity (180°). Useful to fix wrongly soldered cables or to eliminate sound
and phase errors.
Mute
Muting a channel. Allows to remove a signal without the need to change the current gain.
Phones 1 and 2 has the following entries:
Volume
Sets the output level from -64 dB up to +6 dB, in steps of 1 dB. Mute is also available.
Balance
Adjustable from -1 (left) through 0 (middle) to +1 (right).
Source
Selection of the signal source. Play 1/2 and 3/4 relate to
software playback in Class Compliant mode. Mic 1 to 8
provides monophonic monitoring of the selected input, Mic
1/2 to 7/8 the same in stereo. Mic 1-8S performs a
mixdown of all 8 input channels to the Phones output.
Next choices are single channel and stereo channels of
the digital inputs ADAT, AES and MADI.
Mute
Mute of the phones output, without the need to change the current volume setting..
Phase Invert
Available settings are Off, Both, Left and Right.
Output Level
Can be set to Low or High.

Содержание

Скачать