Samsung SCC-C4207P [6/55] Operation voltage range 3v 13v 3v 13v

Samsung SCC-C4207P [6/55] Operation voltage range 3v 13v 3v 13v
E
109
In Setup Menu Mode
- UP/ DOWN buttons: Use to move the cursor up or down.
- LEFT/ RIGHT buttons: Use to move the cursor left or
right, or to sequentially view the values that can be
assigned to a parameter.
- ENTER button: Use to select a Sub Menu item, and to
accept the current value.
ZOOM/ FOCUS REMOTE terminals
This port is used for ZOOM/FOCUS, MENU CONTROL,
HOME RETURN, and AF by using an external controller.
Depending on the input condition, 4 modes, A, B, C, and
D are available. (SPECIAL - CTRL TYPE)
(Operation Voltage Range : +3V~+13V, -3V~-13V)
1)
When the voltage is supplied to either ZOOM or FOCUS port,
1: During MENU OFF, controls ZOOM/FOCUS and
during MENU ON, changes the direction, Up, Down,
Left, and Right.
2) When the voltage is supplied to both ports
2: For short voltage supply during MENU OFF,
executes AF and for more than 2 second
3: For more than 2 second long voltage supply, moves
to the PRESET 0(HOME) position.
DAY/NIGHT External Signal Input & Alarm Signal
Output
This is a function to receive the external DAY/NIGHT
signal from the sensor(option) and convert the signal into
BW. An alarm signal is output from this terminal when the
MOTION DET mode is activated or BW mode is activated.
Connect an external sensor to the DAY/NIGHT terminal
as shown in
then connect any external device such as
a buzzer or lamp to the ALARM terminal as shown in
.
The ALARM output terminal is an open collector with the
following capacity: DC 16V and 100mA.
OFF : Open contact
ON : Below 100mA
The DAY/NIGHT input terminal has the input of DC 5V
pull-up and over 0.2mA.
OFF : Open contact
ON : Closed contact
VIDEO OUT terminal
Connect the monitor's VIDEO IN. The video signal from
the camera is transmitted to the monitor via this terminal.
RS485 terminal
RS485 remote control terminal.
Power LED
Lights when power is on.
POWER IN terminal
Plug in the power adapter here.
Function
1
A
B
C
D
TELE(Up)
-6V
-6V
+6V
+6V
ZOOM Port
FOCUS Port
WIDE(Down)
+6V
+6V
-6V
-6V
NEAR(Left)
-6V
+6V
-6V
+6V
FAR(Right)
+6V
-6V
+6V
-6V
Code
Function
A
B
C
D
-6V
-6V
+6V
+6V
ZOOM Port
FOCUS Port
ENTER/AF 2
HOME RETURN 3
ZOOM Port
FOCUS Port
-6V
+6V
-6V
+6V
+6V
+6V
-6V
-6V
+6V
-6V
+6V
-6V
Code
DAY/NIGHT IN
ALARM OUT
GND
1
2
00544A_C4207(P)-E+R+P 6/5/06 10:29 AM ˘` 9

Содержание

In Setup Menu Mode E1 DAY NIGHT External Signal Input Alarm Signal Output g UP DOWN buttons Use to move the cursor up or down This is a function to receive the external DAY NIGHT signal from the sensor option and convert the signal into gg LEFT RIGHT buttons Use to move the cursor left or BW An alarm signal is output from this terminal when the MOTION DET mode is activated or BW mode is activated right or to sequentially view the values that can be assigned to a parameter 0 ENTER button Use to select a Sub Menu item and to accept the current value S3 ZOOM FOCUS REMOTE terminals This port is used for ZOOM FOCUS MENU CONTROL HOME RETURN and AF by using an external controller Depending on the input condition 4 modes A B C and D are available SPECIAL CTRL TYPE Connect an external sensor to the DAY NIGHT terminal Operation Voltage Range 3V 13V 3V 13V as shown in then connect any external device such as 1 When the voltage is supplied to either ZOOM or FOCUS port a buzzer or lamp to the ALARM terminal as shown in The ALARM output terminal is an open collector with the Function TELE Up Code WIDE Down NEAR Left ZOOM Port FAR Right following capacity DC 16V and 100mA FOCUS Port A 6V 6V 6V 6V B 6V 6V t6V 6V c t6V 6V 6V êV D 6V 6V 6V 6V OFF Open contact ON Below 100mA The DAY NIGHT input terminal has the input of DC 5V pull up and over 0 2mA 1 During MENU OFF controls ZOOM FOCUS and during MENU ON changes the direction Up Down OFF Open contact Left and Right ON Closed contact 2 When the voltage is supplied to both ports Fu fiction Code ENTER AF 2 ZOOM Port g VIDEO OUT terminal HOME RETURN 3 FOCUS Port ZOOM Port FOCUS Port A 6V 6V 6V 6V B 6V 6V 6V 6V C 6V 6V 6V D 6V 6V 6V 2 For short voltage supply during MENU OFF têV 6V Connect the monitor s VIDEO IN The video signal from the camera is transmitted to the monitor via this terminal pg RS485 terminal RS485 remote control terminal Power LED Lights when power is on executes AF and for more than 2 second g POWER IN terminal 3 For more than 2 second long voltage supply moves to the PRESET O HOME position 9 Plug in the power adapter here 10