Alarm reasonAlarm type
Preset alarm time is reached.
Continuous beep series for 24 seconds or until any
button is pressed.
Current time blinks for one minute
Table 5.3. Oxygen alarms in NITROX mode
Alarm reasonAlarm type
Set oxygen partial pressure limit is exceeded.The
alternative display is replaced with a current blinking PO
2
value.You should immediately ascend above the PO
2
depth limit.
Continuous beeps for 3 minutes
and activated backlight
OLF value reaches 80%.The OLF value will start to
blink.
OLF value reaches 100%.The OLF value will blink.
NOTE
When the backlight is turned OFF, it does not illuminate when an
alarm is activated.
WARNING
WHEN THE OXYGEN LIMIT FRACTION INDICATES THAT THE
MAXIMUM LIMIT IS REACHED, YOU MUST IMMEDIATELY TAKE
ACTION TO REDUCE OXYGEN EXPOSURE. Failure to take action
to reduce oxygen exposure after the warning is given can rapidly
increase the risk of oxygen toxicity, injury, or death.
5.6. Error conditions
The dive computer has warning indicators that alert you to react to certain situations that
would significantly increase the risk of DCI. If you do not respond to its warnings, the dive
computer will enter an Error mode, indicating that the risk of DCI has greatly increased.
If you understand the dive computer and operate it sensibly, it is very unlikely you will ever
put the instrument into the Error mode.
Omitted decompression
The Error mode results from omitted decompression, i.e. when you stay above the ceiling
for more than three minutes. During this three-minute period the Er warning is shown and
the audible alarm beeps. After this, the dive computer will enter a permanent Error mode.
The instrument will continue to function normally if you descend below the ceiling within
this three-minute period.
Once in the permanent Error mode, only the Er warning is shown in the center window.
The dive computer will not show times for ascent or stops. However, all the other displays
will function as before to provide information for ascent.You should immediately ascend
to a depth of 3 to 6 m/10 to 20 ft and remain at this depth until air supply limitations require
you to surface.
After surfacing, you should not dive for a minimum of 48 hours. During the permanent
Error mode, the Er text will be displayed in the center window and the planning mode will
be disabled.
5.7.Wireless transmission
The Vyper
AIR
can be used together with an optional wireless cylinder pressure transmitter
that easily attaches to the high-pressure port of the regulator. By using the transmitter,
you can benefit from receiving cylinder pressure and remaining air time data direct to your
wrist.
18
Содержание
- User s guide p.1
- Table of contents p.3
- Welcome to the world of suunto diving instruments p.5
- Warnings cautions and notes p.6
- Suunto at a glance p.9
- Navigating in the menus p.9
- Button symbols and functions p.9
- Time mode settings p.11
- Setting the time p.11
- Setting the date p.11
- Setting the alarm p.11
- Getting started with your suunto vyper air p.11
- Setting the units p.12
- Setting the tones p.12
- Setting the backlight p.12
- Ac water contacts p.12
- Locking a bearing p.13
- Learning how to use your compass p.13
- Compass display p.13
- Calibration p.14
- Compass settings p.14
- You can exit the compass mode also by long pressing the select button p.15
- Time out you can set the compass time out to 1 3 or 5 minutes after the set time has passed from the latest button press the dive computer returns to the time or dive mode from the compass mode p.15
- Time out p.15
- If the calibration fails several times in a row it is possible that you are in an area with sources of magnetism such as large metal objects power lines or electric appliances move to another location and try to calibrate the compass again if the calibration continues to fail contact an authorized suunto service center p.15
- Declination you can compensate for the difference between true north and magnetic north by adjusting the compass declination the declination can be found for example from sea charts or topographic maps of the local area p.15
- Declination p.15
- The suunto rgbm deep stop algorithm p.16
- Emergency ascents p.16
- Dive computer limitations p.16
- Before diving p.16
- Nitrox p.17
- Audible and visual alarms p.17
- Wireless transmission p.18
- Error conditions p.18
- Installing the wireless transmitter p.19
- Pairing and code selection p.19
- Transmitting data p.20
- Dive mode settings p.20
- Setting the nitrox values p.21
- Setting the dive time alarm p.21
- Setting the depth alarm p.21
- Setting the sample rate p.22
- Setting the safety stops deep stops p.22
- Setting the personal altitude adjustments p.22
- Setting the units p.23
- Setting the tank pressure alarm p.23
- Setting the tank pressure p.23
- Setting the rgbm values p.23
- Setting the hp code p.23
- Activation and pre checks p.24
- Accessing dive mode p.24
- Dive mode activation p.24
- Diving at altitude p.25
- Battery power indication p.25
- Personal adjustments p.26
- Safety stops p.27
- Recommended safety stops p.27
- Mandatory safety stops p.27
- Deep stops p.28
- Diving in air mode diveair p.29
- Diving p.29
- Basic dive data p.29
- Tank pressure data p.30
- Bookmark p.30
- Safety stops p.31
- Decompression dives p.31
- Ascent rate indicator p.31
- Ceiling ceiling zone floor and decompression range p.32
- Display below the floor p.33
- Display at the ceiling zone p.33
- Display above the floor p.33
- Display above the ceiling p.33
- Oxygen displays p.34
- Diving in nitrox mode divenitrox p.34
- Default nitrox settings p.34
- Before diving in nitrox mode p.34
- Oxygen limit fraction olf p.35
- Gas change and multiple breathing gas mixes p.35
- Diving in gauge mode divegauge p.36
- Surface interval p.37
- Repetitive dive planning p.37
- Dive numbering p.37
- After diving p.37
- Plan mode p.38
- Flying after diving p.38
- Dive planning mode plannodec p.38
- Simulation mode plansimulator p.39
- Dive simulator p.39
- Dive numbering shown during dive planning p.39
- Memory mode p.40
- Dive logbook memlogbook p.40
- Dive history memhistory p.41
- Www suuntosports com and suunto diving world at www suunto com diving p.42
- Suunto dive manager sdm p.42
- Care and maintenance of my suunto diving computer p.44
- Required tools p.46
- Replacing the battery p.46
- Battery replacement p.46
- Battery kit p.46
- Wireless transmitter battery replacement p.48
- Transmitter battery kit p.48
- Required tools p.48
- Replacing the transmitter battery p.48
- Technical specifications p.50
- Technical data p.50
- Suunto rgbm adaptive decompression p.52
- No decompression limits p.52
- Oxygen exposure p.53
- Altitude diving p.53
- Trademark p.55
- Patent notice p.55
- Intellectual property p.55
- Copyright p.55
- User s responsibility p.56
- Disclaimers p.56
- Suunto limited warranty for suunto diving computers and suunto diving computer accessories p.57
- Disposal of the device p.60
- Glossary p.61
- Customer service contacts p.63
- Copyright p.63
- Two year warranty p.64
- Www suunto com p.65
Похожие устройства
-
Suunto CobraИнструкция по эксплуатации -
Suunto Cobra2Инструкция по эксплуатации -
Suunto Cobra3Инструкция по эксплуатации -
Suunto ComboИнструкция по эксплуатации -
Suunto D4iИнструкция по эксплуатации -
Suunto D6Инструкция по эксплуатации -
Suunto D6iИнструкция по эксплуатации -
Suunto D9Инструкция по эксплуатации -
Suunto D9txИнструкция по эксплуатации -
Suunto GekkoИнструкция по эксплуатации -
Suunto HelO2Инструкция по эксплуатации -
Suunto StingerИнструкция по эксплуатации
Информация о типах ошибок и предупреждений подводного компьютера, включая ограничения кислорода, декомпрессию и беспроводные функции для безопасного погружения.