Suunto Vyper Air — основные аспекты безопасности при подводном погружении [31/65]
Превью страниц
Страница 31 /
65
![Suunto Vyper Air [31/65] Safety stops](/views2/1013562/page31/bg1f.png)
NOTE
Filling your BC affects the air time calculation due to the temporary
increase in air consumption.
NOTE
A change of temperature will affect the cylinder pressure and
consequently the air time calculation.
Low Air Pressure Warnings
The dive computer will warn you with three audible double beeps and a blinking pressure
display when the cylinder pressure reaches 50 bar/725 psi.
Three double beeps are also heard when the cylinder pressure goes down to the
user-selected alarm pressure and when the remaining air time reaches zero.
6.1.4. Ascent rate indicator
The ascent rate is shown graphically along the right hand side.When the maximum allowed
ascent rate is exceeded, the lower segments start to blink with the top segment staying
solid, indicating that the maximum ascent rate has been exceeded continuously or that
the current ascent rate is significantly above the allowed rate.
NORMAL
ASCENT
RATE.
ACTIVATED BACKLIGHT,
ALARM AND A BLINKING ASCENT
RATE BAR GRAPH INDICATE YOU
ARE ASCENDING FASTER THAN 10
M/MIN. YOU ARE ADVISED TO
MAKE A MANDATORY SAFETY
STOP WHEN YOU REACH A
DEPTH OF 6 M.
WARNING
DO NOT EXCEED THE MAXIMUM ASCENT RATE! Rapid ascents
increase the risk of injury. You should always make the Mandatory
and Recommended Safety Stops after you have exceeded the
maximum recommended ascent rate. If this Mandatory Safety Stop
is not completed, the decompression model will penalize your next
dive(s). Continuous ascent rate violations will result in Mandatory
Safety Stops.When Recommended Deep Stop is enabled, the length
is indicated in seconds.
6.1.5. Safety Stops
A 3 minute Recommended Safety Stop is prompted after every dive to over 10m.
6.1.6. Decompression dives
When your NO DEC TIME becomes zero, your dive becomes a decompression dive so
you must perform one or more decompression stops on your way to the surface.The NO
DEC TIME on your display will be replaced by an ASC TIME, and a CEILING notation will
appear. An upward pointing arrow will also prompt you to start your ascent.
If you exceed the no-decompression limits on a dive, the dive computer will provide the
decompression information required for ascent. After this, the instrument will continue to
provide subsequent interval and repetitive dive information.
Rather than requiring you to make stops at fixed depths, the dive computer lets you
decompress within a range of depths (continuous decompression).
The ascent time (ASC TIME) is the minimum amount of time needed to reach the surface
in a decompression dive. It includes:
•
the time needed to ascend to the ceiling at an ascent rate of 10 m/33 ft per minute.
The ceiling is the shallowest depth to which you should ascend
31
Содержание
- User s guide p.1
- Table of contents p.3
- Welcome to the world of suunto diving instruments p.5
- Warnings cautions and notes p.6
- Suunto at a glance p.9
- Navigating in the menus p.9
- Button symbols and functions p.9
- Time mode settings p.11
- Setting the time p.11
- Setting the date p.11
- Setting the alarm p.11
- Getting started with your suunto vyper air p.11
- Setting the units p.12
- Setting the tones p.12
- Setting the backlight p.12
- Ac water contacts p.12
- Locking a bearing p.13
- Learning how to use your compass p.13
- Compass display p.13
- Calibration p.14
- Compass settings p.14
- You can exit the compass mode also by long pressing the select button p.15
- Time out you can set the compass time out to 1 3 or 5 minutes after the set time has passed from the latest button press the dive computer returns to the time or dive mode from the compass mode p.15
- Time out p.15
- If the calibration fails several times in a row it is possible that you are in an area with sources of magnetism such as large metal objects power lines or electric appliances move to another location and try to calibrate the compass again if the calibration continues to fail contact an authorized suunto service center p.15
- Declination you can compensate for the difference between true north and magnetic north by adjusting the compass declination the declination can be found for example from sea charts or topographic maps of the local area p.15
- Declination p.15
- The suunto rgbm deep stop algorithm p.16
- Emergency ascents p.16
- Dive computer limitations p.16
- Before diving p.16
- Nitrox p.17
- Audible and visual alarms p.17
- Wireless transmission p.18
- Error conditions p.18
- Installing the wireless transmitter p.19
- Pairing and code selection p.19
- Transmitting data p.20
- Dive mode settings p.20
- Setting the nitrox values p.21
- Setting the dive time alarm p.21
- Setting the depth alarm p.21
- Setting the sample rate p.22
- Setting the safety stops deep stops p.22
- Setting the personal altitude adjustments p.22
- Setting the units p.23
- Setting the tank pressure alarm p.23
- Setting the tank pressure p.23
- Setting the rgbm values p.23
- Setting the hp code p.23
- Activation and pre checks p.24
- Accessing dive mode p.24
- Dive mode activation p.24
- Diving at altitude p.25
- Battery power indication p.25
- Personal adjustments p.26
- Safety stops p.27
- Recommended safety stops p.27
- Mandatory safety stops p.27
- Deep stops p.28
- Diving in air mode diveair p.29
- Diving p.29
- Basic dive data p.29
- Tank pressure data p.30
- Bookmark p.30
- Safety stops p.31
- Decompression dives p.31
- Ascent rate indicator p.31
- Ceiling ceiling zone floor and decompression range p.32
- Display below the floor p.33
- Display at the ceiling zone p.33
- Display above the floor p.33
- Display above the ceiling p.33
- Oxygen displays p.34
- Diving in nitrox mode divenitrox p.34
- Default nitrox settings p.34
- Before diving in nitrox mode p.34
- Oxygen limit fraction olf p.35
- Gas change and multiple breathing gas mixes p.35
- Diving in gauge mode divegauge p.36
- Surface interval p.37
- Repetitive dive planning p.37
- Dive numbering p.37
- After diving p.37
- Plan mode p.38
- Flying after diving p.38
- Dive planning mode plannodec p.38
- Simulation mode plansimulator p.39
- Dive simulator p.39
- Dive numbering shown during dive planning p.39
- Memory mode p.40
- Dive logbook memlogbook p.40
- Dive history memhistory p.41
- Www suuntosports com and suunto diving world at www suunto com diving p.42
- Suunto dive manager sdm p.42
- Care and maintenance of my suunto diving computer p.44
- Required tools p.46
- Replacing the battery p.46
- Battery replacement p.46
- Battery kit p.46
- Wireless transmitter battery replacement p.48
- Transmitter battery kit p.48
- Required tools p.48
- Replacing the transmitter battery p.48
- Technical specifications p.50
- Technical data p.50
- Suunto rgbm adaptive decompression p.52
- No decompression limits p.52
- Oxygen exposure p.53
- Altitude diving p.53
- Trademark p.55
- Patent notice p.55
- Intellectual property p.55
- Copyright p.55
- User s responsibility p.56
- Disclaimers p.56
- Suunto limited warranty for suunto diving computers and suunto diving computer accessories p.57
- Disposal of the device p.60
- Glossary p.61
- Customer service contacts p.63
- Copyright p.63
- Two year warranty p.64
- Www suunto com p.65
Похожие устройства
-
Suunto CobraИнструкция по эксплуатации -
Suunto Cobra2Инструкция по эксплуатации -
Suunto Cobra3Инструкция по эксплуатации -
Suunto ComboИнструкция по эксплуатации -
Suunto D4iИнструкция по эксплуатации -
Suunto D6Инструкция по эксплуатации -
Suunto D6iИнструкция по эксплуатации -
Suunto D9Инструкция по эксплуатации -
Suunto D9txИнструкция по эксплуатации -
Suunto GekkoИнструкция по эксплуатации -
Suunto HelO2Инструкция по эксплуатации -
Suunto StingerИнструкция по эксплуатации
Узнайте о важности контроля давления и скорости подъема при подводных погружениях. Соблюдайте правила безопасности для предотвращения травм и соблюдения декомпрессии.