Suunto Vyper Air — how to Set Depth, Time Alarms and Nitrox on Diving Computers [21/65]
Превью страниц
Страница 21 /
65
![Suunto Vyper Air [21/65] Setting the nitrox values](/views2/1013562/page21/bg15.png)
NOTE
Some settings cannot be changed until 5 minutes has elapsed after
the dive.
5.8.1. Setting the depth alarm
You can set a depth alarm in the dive computer.
ADJUST WITH UP AND
DOWN BUTTONS. ACCEPT
WITH SELECT BUTTON.
The depth alarm is factory-set to 30 m/100 ft, but you can adjust it according to your
personal preference, or switch it off altogether. The depth range can be set from 3 m to
100 m/9 ft to 328 ft.
5.8.2. Setting the dive-time alarm
The Suunto Vyper
AIR
has a dive-time alarm setting which, when activated, can be used
for several purposes to add to your diving safety.
ADJUST WITH UP AND
DOWN BUTTONS. ACCEPT
WITH SELECT BUTTON.
NOTE
With a range of 1 - 999 minutes, the alarm can be set to your planned
bottom time, for example.
5.8.3. Setting the nitrox values
If set to the NITROX mode, the correct oxygen percentage of the gas in your cylinder (and
additional gases) must always be entered into the computer to ensure correct nitrogen
and oxygen calculations. In addition, the oxygen partial pressure limit must be set.When
in the NITROX setting mode, the equivalent allowed maximum depth, based on the chosen
setting, will also be displayed.
Settings for an additional mix (MIX2) are made similarly, but with the additional selection
of “ON” or “OFF”.
In order to minimize the risk of error during a dive, it is highly recommended that the mixes
are set in the proper order. This means that as the mix number rises, so does oxygen
content, and this is the order they are usually used during the dive. Before a dive, only set
to “ON” the mixes you actually have available and remember to check the set values to
make sure they are correct.
The default oxygen percentage (O
2
%) setting is 21% (air) and oxygen partial pressure
(PO
2
) setting 1.4 bar.
After entering values for MIX1, you can enable/disable and set an additional gas mix -
MIX2.
21
Содержание
- User s guide p.1
- Table of contents p.3
- Welcome to the world of suunto diving instruments p.5
- Warnings cautions and notes p.6
- Suunto at a glance p.9
- Navigating in the menus p.9
- Button symbols and functions p.9
- Time mode settings p.11
- Setting the time p.11
- Setting the date p.11
- Setting the alarm p.11
- Getting started with your suunto vyper air p.11
- Setting the units p.12
- Setting the tones p.12
- Setting the backlight p.12
- Ac water contacts p.12
- Locking a bearing p.13
- Learning how to use your compass p.13
- Compass display p.13
- Calibration p.14
- Compass settings p.14
- You can exit the compass mode also by long pressing the select button p.15
- Time out you can set the compass time out to 1 3 or 5 minutes after the set time has passed from the latest button press the dive computer returns to the time or dive mode from the compass mode p.15
- Time out p.15
- If the calibration fails several times in a row it is possible that you are in an area with sources of magnetism such as large metal objects power lines or electric appliances move to another location and try to calibrate the compass again if the calibration continues to fail contact an authorized suunto service center p.15
- Declination you can compensate for the difference between true north and magnetic north by adjusting the compass declination the declination can be found for example from sea charts or topographic maps of the local area p.15
- Declination p.15
- The suunto rgbm deep stop algorithm p.16
- Emergency ascents p.16
- Dive computer limitations p.16
- Before diving p.16
- Nitrox p.17
- Audible and visual alarms p.17
- Wireless transmission p.18
- Error conditions p.18
- Installing the wireless transmitter p.19
- Pairing and code selection p.19
- Transmitting data p.20
- Dive mode settings p.20
- Setting the nitrox values p.21
- Setting the dive time alarm p.21
- Setting the depth alarm p.21
- Setting the sample rate p.22
- Setting the safety stops deep stops p.22
- Setting the personal altitude adjustments p.22
- Setting the units p.23
- Setting the tank pressure alarm p.23
- Setting the tank pressure p.23
- Setting the rgbm values p.23
- Setting the hp code p.23
- Activation and pre checks p.24
- Accessing dive mode p.24
- Dive mode activation p.24
- Diving at altitude p.25
- Battery power indication p.25
- Personal adjustments p.26
- Safety stops p.27
- Recommended safety stops p.27
- Mandatory safety stops p.27
- Deep stops p.28
- Diving in air mode diveair p.29
- Diving p.29
- Basic dive data p.29
- Tank pressure data p.30
- Bookmark p.30
- Safety stops p.31
- Decompression dives p.31
- Ascent rate indicator p.31
- Ceiling ceiling zone floor and decompression range p.32
- Display below the floor p.33
- Display at the ceiling zone p.33
- Display above the floor p.33
- Display above the ceiling p.33
- Oxygen displays p.34
- Diving in nitrox mode divenitrox p.34
- Default nitrox settings p.34
- Before diving in nitrox mode p.34
- Oxygen limit fraction olf p.35
- Gas change and multiple breathing gas mixes p.35
- Diving in gauge mode divegauge p.36
- Surface interval p.37
- Repetitive dive planning p.37
- Dive numbering p.37
- After diving p.37
- Plan mode p.38
- Flying after diving p.38
- Dive planning mode plannodec p.38
- Simulation mode plansimulator p.39
- Dive simulator p.39
- Dive numbering shown during dive planning p.39
- Memory mode p.40
- Dive logbook memlogbook p.40
- Dive history memhistory p.41
- Www suuntosports com and suunto diving world at www suunto com diving p.42
- Suunto dive manager sdm p.42
- Care and maintenance of my suunto diving computer p.44
- Required tools p.46
- Replacing the battery p.46
- Battery replacement p.46
- Battery kit p.46
- Wireless transmitter battery replacement p.48
- Transmitter battery kit p.48
- Required tools p.48
- Replacing the transmitter battery p.48
- Technical specifications p.50
- Technical data p.50
- Suunto rgbm adaptive decompression p.52
- No decompression limits p.52
- Oxygen exposure p.53
- Altitude diving p.53
- Trademark p.55
- Patent notice p.55
- Intellectual property p.55
- Copyright p.55
- User s responsibility p.56
- Disclaimers p.56
- Suunto limited warranty for suunto diving computers and suunto diving computer accessories p.57
- Disposal of the device p.60
- Glossary p.61
- Customer service contacts p.63
- Copyright p.63
- Two year warranty p.64
- Www suunto com p.65
Похожие устройства
-
Suunto CobraИнструкция по эксплуатации -
Suunto Cobra2Инструкция по эксплуатации -
Suunto Cobra3Инструкция по эксплуатации -
Suunto ComboИнструкция по эксплуатации -
Suunto D4iИнструкция по эксплуатации -
Suunto D6Инструкция по эксплуатации -
Suunto D6iИнструкция по эксплуатации -
Suunto D9Инструкция по эксплуатации -
Suunto D9txИнструкция по эксплуатации -
Suunto GekkoИнструкция по эксплуатации -
Suunto HelO2Инструкция по эксплуатации -
Suunto StingerИнструкция по эксплуатации
Learn to configure depth and time alarms, set nitrox values for safe diving, and adjust your dive computer settings. Includes step-by-step guidance for various alarm systems and configurations to enhance underwater safety.