Zyxel IES-1248 EE [308/544] Log messages

Zyxel IES-1248 EE [308/544] Log messages
Chapter 47 Diagnostic
IES-1248-51/51A/53 User’s Guide
308
47.2.1 Log Messages
The following table lists and describes the system log messages.
Table 108 Log Messages
LOG MESSAGE TYPE DESCRIPTION
ADSL <port> Link
Up(SN=<seq no>): <ds
rate>/<us rate>!
or
ADSL Link Info: NM:<ds
NM>/<us NM>!
INFO An ADSL port established a connection.
<port> - port number
<seq no> - sequence number of the connection
<ds rate> - downstream rate
<us rate> - upstream rate
<us NM> - upstream noise margin
<ds NM> - downstream noise margin
ADSL <port> Link
Down(SN=<seq no>)!
WARN An ADSL port lost its connection.
<port> - port number
<seq no> - sequence number of the connection
Session Begin! INFO A console, telnet or FTP session has begun (see the
<process> field for the type of session).
Session End! INFO A console telnet or FTP session has terminated (see the
<process> field for the type of session).
Incorrect Password! WARN Someone attempted to use the wrong password to start a
console, telnet or FTP session (see the <process> field for
the type of session).
Received Firmware
Checksum Error!
WARN A checksum error was detected during an attempted FTP
firmware upload.
Received Firmware Size
too large!
WARN The file size was too large with an attempted FTP firmware
upload.
Received Firmware
Invalid!
WARN Someone attempted to upload a firmware file with a wrong
identity via FTP.
Received File <file>! INFO A file was uploaded to the IES-1248 by FTP.
<file> - received file’s name
THERMO OVER
TEMPERATURE: dev:<id>
threshold:<threshold>
(degree C)
value:<temp>(degree
C)!
WARN The temperature was too high at one of the temperature
sensors.
<id> -
0: sensor near the ADSL chipset
1: sensor near the CPU
2: thermal sensor chip itself
<threshold> - threshold temperature
<temp> - temperature when the entry was logged
THERMO OVER
TEMPERATURE released:
dev:<id>
threshold:<threshold>
(degree C)
value:<temp>(degree
C)!
INFO The temperature at one of the temperature sensors has come
back to normal.
<id>
0: sensor near the ADSL chipset
1: sensor near the CPU
2: thermal sensor chip itself
<threshold> - threshold temperature
<temp> - temperature when the entry was logged

Содержание