Zyxel IES-1248 EE [381/544] Vlan cpu show command

Zyxel IES-1248 EE [381/544] Vlan cpu show command
Chapter 54 IEEE 802.1Q Tagged VLAN Commands
IES-1248-51/51A/53 User’s Guide
381
" The IES-1248 accepts both tagged and untagged incoming frames on the
Ethernet ports.
The following example sets the IES-1248 to accept only VLAN tagged Ethernet frames on
DSL port 3.
54.4.6 VLAN CPU Show Command
Syntax:
ras> switch vlan cpu show
This command displays the management VLAN (CPU). You can only use ports that are
members of this management VLAN in order to manage the IES-1248.
The following example sets VLAN ID 2 to be the CPU (management) VLAN.
54.4.7 VLAN CPU Set Command
Syntax:
ras> switch vlan cpu set <vid>
where
This command sets the management VLAN (CPU). You can only use ports that are members
of this management VLAN in order to manage the IES-1248.
The following example sets VLAN ID 2 to be the CPU (management) VLAN.
54.4.8 Configuring Management VLAN Example
" After the following example configuration, you must connect to the first
Ethernet port through a VLAN aware device that is using the proper VLAN ID
in order to perform management.
Figure 189 VLAN Frame Type Command Example
ras> switch vlan frametype 3 tag
Figure 190 VLAN CPU Set Command Example
ras> switch vlan cpu set 2
<vid> =
The VLAN ID. Valid parameter range = [1 – 4094].
Figure 191 VLAN CPU Set Command Example
ras> switch vlan cpu set 2