Zyxel IES-1248 EE [508/544] Be careful not to lock yourself and others out of the system

Zyxel IES-1248 EE [508/544] Be careful not to lock yourself and others out of the system
Chapter 66 Troubleshooting
IES-1248-51/51A/53 User’s Guide
508
66.10 Data Rate
The SYNC-rate is not the same as the configured rate.
66.11 Configured Settings
The configured settings do not take effect.
66.12 Password
If you forget your password, you will need to use the console port to reload the factory-default
configuration file (see Section 66.16 on page 509).
66.13 System Lockout
Any of the following could also lock you and others out from using in-band management
(managing through the data ports).
1 Deleting the management VLAN (default is VLAN 1).
2 Incorrectly configuring the CPU VLAN.
3 Incorrectly configuring the access control settings.
4 Disabling all ports.
" Be careful not to lock yourself and others out of the system.
If you lock yourself (and others) out of the system, you can try using the console port to
reconfigure the system. See Section 66.16 on page 509.
Table 135 Troubleshooting the SYNC-rate
STEPS CORRECTIVE ACTION
1 Connect the ADSL modem or router directly to the ADSL port using a different telephone
wire.
2 If the rates match, the quality of the telephone wiring that connects the subscriber to the
ADSL port may be limiting the speed to a certain rate.
If they do not match when a good wire is used, contact the distributor.
Table 136 Troubleshooting the IES-1248’s Configured Settings
CORRECTIVE ACTION
Use the “config save” command after you finish configuring to save the IES-1248’s settings.