Zyxel IES-1248 EE [467/544] Alarm profile set command

Zyxel IES-1248 EE [467/544] Alarm profile set command
Chapter 63 ADSL Commands
IES-1248-51/51A/53 User’s Guide
467
63.3.2 Alarm Profile Set Command
Syntax:
ras> adsl alarmprofile set <profile> [<atuc lofs> <atur lofs> <atuc loss>
<atur loss> <atuc lols> <atuc lprs> <atur lprs> <atuc ess> <atur ess> <atuc
fast rateup> <atur fast rateup> <atuc interleave rateup> <atur interleave
rateup> <atuc fast ratedown> <atur fast ratedown> <atuc interleave ratedown>
<atur interleave ratedown> <init fail enable> <atuc fail fast> <atuc ses>
<atur ses> <atuc uas> <atur uas>]
where
<profile> =
A name for the alarm profile (up to 31 ASCII characters).
atuc =
Upstream. These parameters are for the connection (or traffic)
coming from the subscribers device to the IES-1248.
atur =
Downstream. These parameters are for the connection (or
traffic) going from the IES-1248 to the subscribers device.
<atuc lofs>
<atur lofs>
=
The number of Loss Of Frame seconds that are permitted to
occur within 15 minutes.
<atuc loss>
<atur loss>
=
The number of Loss Of Signal seconds that are permitted to
occur within 15 minutes.
<atuc lols> =
The number of Loss Of Link seconds that are permitted to occur
within 15 minutes.
<atuc lprs>
<atur lprs>
=
The number of Loss of Power seconds that are permitted to
occur (on the ATUR) within 15 minutes.
<atuc ess>
<atur ess>
=
The number of Errored Seconds that are permitted to occur
within 15 minutes.
<atuc fast
rateup> <atur
fast rateup>
=
A rate in kilobits per second (kbps). If a fast mode connection’s
upstream transmission rate increases by more than this number,
then a trap is sent.
<atuc
interleave
rateup> <atur
interleave
rateup>
=
A rate in kilobits per second (kbps). If an interleave mode
connection’s upstream transmission rate increases by more than
this number, then a trap is sent.
<atuc fast
ratedown> <atur
fast ratedown>
=
A rate in kilobits per second (kbps). If a fast mode connection’s
downstream transmission rate decreases by more than this
number, then a trap is sent.
<atuc
interleave
ratedown> <atur
interleave
ratedown>
=
A rate in kilobits per second (kbps). If an interleave mode
connection’s upstream transmission rate decreases by more than
this number, then a trap is sent.
<init fail
enable>
=
“1” sets the profile to trigger an alarm for an initialization
failures trap. “2” sets the profile to not trigger an alarm for an
initialization failures trap.
<atuc fail
fast>
=
The number of failed fast retrains that are permitted to occur
within 15 minutes.