Zyxel IES-1248 EE [334/544] Chapter 50 commands

Zyxel IES-1248 EE [334/544] Chapter 50 commands
Chapter 50 Commands
IES-1248-51/51A/53 User’s Guide
334
xedit <alarm>|all
<cond>|<condcode>
<severity> <fac>
<target>[,<target>
] [clearable]
Sets the severity level of an
alarm(s) and where the system is
to send the alarm(s).
Use the alarm tablelist
command to display alarm setting
details.
<cond>: all|condition This
is the text description for the
condition under which the alarm
applies. Use the alarm
tablelist to find alarm
conditions.
<condcode>: The condition
code is the number of a specific
alarm message. Use the alarm
tablelist to find alarm
condition codes.
<severity>: Specify an alarm
severity level (critical, major,
minor or info) for this alarm.
Critical alarms are the most
severe, major alarms are the
second most severe, minor
alarms are the third most severe
and info alarms are the least
severe.
<fac>: The log facility
(local1~local7) has the device
log the syslog messages to a
particular file in the syslog server.
Set this if this entry is for sending
alarms to a syslog server. See
your syslog program’s
documentation for details.
<target>: snmp|syslog|all
The type of alarm messages that
the device is to send (SNMP,
syslog or all). You can specify
more than one, separated by
commas.
clearable|unclearable This
sets whether or not the alarm
clear command removes the
alarm from the system.
M/L
switch
acl delete <portlist> <vpi>
<vci> <profile>
Remove an acl profile from PVC
<profile>: string32
up to 8 profiles if only one PVC
has profiles
M/H
acl profile delete <name> delete an acl profile M/H
Table 113 Commands (continued)
CLASS COMMAND PARAMETERS DESCRIPTION P