Graco ProControl 1KS [22/138] Manual override screen

Graco ProControl 1KS [22/138] Manual override screen
Run Mode Screens
22 3A1080F
Manual Override Screen
This screen will appear if Manual Override is set to “On”
in Advanced Setup Screen 1 (page 35). It shows the
active recipe, new/go to recipe, and manual override
mode.
If Flow Control is set to “On” in Configure Screen 5 on
page 30, this screen will also display Flow Rate Range,
Flow Set Point, Flow Control Calibration (Start/Abort),
and Global Flow Control Data Copy (Start/Abort).
Manual Override Menu
This field allows you to set the operating mode from the
EasyKey. Press the Enter key to view the menu,
then select the desired operating mode (Standby, Mix,
Purge, or Recipe Change). See F
IG. 13.
Flow Rate Range
This screen displays the flow rate range selected on
Advanced Setup Screen 5 (see page 37).
Flow Set Point
The Flow Set Point is user settable. If Flow Control
Override is set to “Off” or “Pressure” in Advanced
Setup Screen 1 on page 35, the Flow Set Point will dis-
play as cc/min. Enter the desired flow set point within
the range.
If Flow Control Override is set to “% Open,” the Flow Set
Point will display as % Open. This percentage relates to
the flow control V/P ratio which translates to a fluid flow
rate. Set the initial percentage at 35% and increase as
necessary to reach the desired flow rate.
Flow Control Calibration
This field allows you to calibrate flow control for each
recipe. The system must be in Mix mode and receiving a
Gun Trigger signal. Press the Enter key to view the
menu, then select Start or Abort. See F
IG. 14.
The flow rate will drop to 0, then incrementally increase
until it reaches the maximum flow rate. To view the
progress, go to the Status Screen, page 21. The sys-
tem will populate the data for the current recipe. To copy
this data to all recipes, see Global Flow Control Data
Copy, page 23.
F
IG. 12. Manual Override Screen
F
IG. 13. Manual Override Menu
FIG. 14. Flow Control Calibration

Содержание

Скачать