Configuring Event Types
Event Types can be divided into two basic groups: System Events and Port Events. System Events are
related to the overall function of the switch, whereas Port Events are related to the activity of a specific port.
System Events Warning e-mail is sent when…
Switch Cold Start Power is cut off and then reconnected.
Switch Warm Start Moxa switch is rebooted, such as when network parameters are changed
(IP address, subnet mask, etc.).
Power Transition (OnOff)
Moxa switch is powered down.
Power Transition (OffOn)
Moxa switch is powered up.
DI1/DI2 (OnOff)
Digital Input 1/2 is triggered by on to off transition
DI1/DI2 (OffOn)
Digital Input 1/2 is triggered by off to on transition
Configuration Change Activated Any configuration item has been changed.
Authentication Failure An incorrect password was entered.
Comm. Redundancy Topology
Changed
If any Spanning Tree Protocol switches have changed their position
(applies only to the root of the tree).
If the Master of the Turbo Ring has changed or the backup path is
activated.
Port Events Warning e-mail is sent when…
Link-ON The port is connected to another device.
Link-OFF The port is disconnected (e.g., the cable is pulled out, or the opposing
device shuts down).
Traffic-Overload The port’s traffic surpasses the Traffic-Threshold for that port (provided
this item is Enabled).
Traffic-Threshold (%) Enter a nonzero number if the port’s Traffic-Overload item is Enabled.
Traffic-Duration (sec.) A Traffic-Overload warning is sent every Traffic-Duration seconds if the
average Traffic-Threshold is surpassed during that time period.
NOTE
The Traffic
-Overload, Traffic-Threshold (%), and Traffic-Duration (sec.) Port Event item
s are related. If you
Enable the Traffic
-Overload event, then be sure to enter a nonzero Traffic-
Threshold percentage, as well as a
Traffic
-Duration between 1 and 300 seconds.
NOTE
The sender of warning e
-mail messages will have the following form:
Managed-Redundant-Switch-00000@Switch_Location
where Managed
-Redundant-Switch-00000 is the default Switch Name, 00000 is the Moxa switch’s serial
number, and Switch_Location is the default Server Location. Refer to the Basic Settings section to see how to
modify Switch Name and Switch Location.