Moxa CP-132S [43/45] Windows 95 98

Moxa CP-132S [43/45] Windows 95 98
CP-132 Series Troubleshooting
6-3
Windows 95/98
This section is specific for troubleshooting under Windows 95/98. For general problems and solutions, please
see the previous section, “General Troubleshooting”.
1. The system fails to find the Industio CP-132 Series board!
The board(s) is(are) not plugged properly.
The slot with boards plugging in is defective, please try another slot until you find a good one.
The board might be defective.
2. After the system reboots, the error message “CP-132 Series (BusNo=x, DevNo=x, Port1=COMx)
interrupt number is invalid!” appears.
This indicates that the MOXA board is found, but the IRQ is conflicting with other adapter. Make sure MOXA
board’s IRQ is not conflicting with other adapter’s. Check the PCI BIOS IRQ settings and select an available
IRQ for MOXA boards.