Moxa DA-683-SP-W7E [26/50] Enhanced write filter

Moxa DA-683-SP-W7E [26/50] Enhanced write filter
DA-683 XPE User's Manual Software Configuration
//Set UART Mode
if(uart_setmode(port,mode)==-1)
{
printf("Set UART Mode Fail!!\n");
}
else
{
printf("COM%d=%s\n",port,mode_array[mode]);
}
break;
}
getwchar();
sin = getwchar();
n = _wtoi(&sin);
} while (n != 0);
return 0;
}
Enhanced Write Filter
The “Enhanced Write Filter” protects the contents of a volume on the target media volume by redirecting all
writes to another storage location called on overlay. Use the following steps to enable the Enhanced Write
Filter.
1. Type EWFMGR C: to check if the state of the Enhanced Write Filter is Disabled.
2. To enable the filter, type EWFMGR C: -enable.
3. Reboot the system to activate the change.
4. Delete a file on your protected volume and reboot the system; the file you just deleted will appear.