Moxa MD-224X [54/56] Md 224 hardware manual display uart commands

Moxa MD-226X [54/56] Md 224 hardware manual display uart commands
MD-224 Hardware Manual Display UART Commands
C-10
MCC Command Syntax and Functionality Details and Values
OSD Horizontal Position Syntax: 07 FF 4D 43 43 03 23 90 xx yy zz
Function Examples:
Example "50": 07 FF 4D 43 43 03 23 90 35 30 0A
Query "?": 07 FF 4D 43 43 02 24 90 3F 30
Reset "R": 07 FF 4D 43 43 02 24 90 52 1D
Reset "r": 07 FF 4D 43 43 02 24 90 72 FD
Increase "+": 07 FF 4D 43 43 02 24 90 2B 44
Decrease "-": 07 FF 4D 43 43 02 24 90 2D 42
Where xx = "0" to "6"
Where yy = "0" to "F"
Where zz = Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "6" "4"100
Note: If Value > 100 then
Value=100.
OSD Vertical Position Syntax: 07 FF 4D 43 43 03 23 91 xx yy zz
Function Examples:
Example "50": 07 FF 4D 43 43 03 23 91 35 30 09
Query "?": 07 FF 4D 43 43 02 24 91 3F 2F
Reset "R": 07 FF 4D 43 43 02 24 91 52 1C
Reset "r": 07 FF 4D 43 43 02 24 91 72 FC
Increase "+": 07 FF 4D 43 43 02 24 91 2B 43
Decrease "-": 07 FF 4D 43 43 02 24 91 2D 41
Where xx = "0" to "6"
Where yy = "0" to "F"
Where zz = Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "6" "4"100
Note: If Value > 100 then
Value=100.
Select OSD Language Syntax: 07 FF 4D 43 43 02 24 95 xx zz
Function Examples:
Example "0": 07 FF 4D 43 43 02 24 95 30 3A
Query "?": 07 FF 4D 43 43 02 24 95 3F 2B
Reset "R": 07 FF 4D 43 43 02 24 95 52 18
Reset "r": 07 FF 4D 43 43 02 24 95 72 F8
Where xx = “0”
Where zz = Calculated Checksum
Available function:
“0” = Englishdefault
Only support English now
Main Input Select Syntax: 07 FF 4D 43 43 02 24 98 xx zz
Function Examples:
Example "0": 07 FF 4D 43 43 02 24 98 30 37
Query "?": 07 FF 4D 43 43 02 24 98 3F 28
Reset "R": 07 FF 4D 43 43 02 24 98 52 15
Reset "r": 07 FF 4D 43 43 02 24 98 72 F5
Where xx = “0” to “1”
Where zz = Calculated Checksum
Available function:
“0” = DVIdefault
“1” = VGA
Communication Mode Syntax: 07 FF 4D 43 43 02 24 99 xx zz
Function Examples:
Example "0": 07 FF 4D 43 43 02 24 99 30 36
Query "?": 07 FF 4D 43 43 02 24 99 3F 27
Reset "R": 07 FF 4D 43 43 02 24 99 52 14
Reset "r": 07 FF 4D 43 43 02 24 99 72 F4
Where xx = “0” to “5
Where zz = Calculated Checksum
Available function:
“0” = DB9_RS232
“1” = TB_RS4852W
“2” = TB_RS422
DB9 and Terminal block connector
Power Down/Up Display Syntax: 07 FF 4D 43 43 02 24 9F xx zz
Function Examples:
Example "1": 07 FF 4D 43 43 02 24 9F 31 2F
Query "?": 07 FF 4D 43 43 02 24 9F 3F 21
Reset "R": 07 FF 4D 43 43 02 24 9F 52 0E
Reset "r": 07 FF 4D 43 43 02 24 9F 72 EE
Where xx = “0” to “1
Where zz = Calculated Checksum
Available function:
“0” = Power Off
“1” = Power Ondefault
Color Temperature Select Syntax: 07 FF 4D 43 43 02 24 B3 xx zz
Function Examples:
Example "2": 07 FF 4D 43 43 02 24 B3 32 1A
Query "?": 07 FF 4D 43 43 02 24 B3 3F 0D
Reset "R": 07 FF 4D 43 43 02 24 B3 52 FA
Reset "r": 07 FF 4D 43 43 02 24 B3 72 DA
Where xx = “0” to “2
Where zz = Calculated Checksum
Available function:
“0” = 9300K
“1” = 7500K
“2” = 6500Kdefault
Red Level for Selected Color Syntax: 07 FF 4D 43 43 03 23 B4 xx yy zz
Function Examples:
Example "50": 07 FF 4D 43 43 03 23 B4 35 30 E6
Query "?": 07 FF 4D 43 43 02 24 B4 3F 0C
Reset "R": 07 FF 4D 43 43 02 24 B4 52 F9
Where xx = "0" to "6"
Where yy = "0" to "F"
Where zz = Calculated Checksum
Max Range: "0" "0" to "6" "4"
Default: "6" "4"100

Содержание