Moxa OnCell G3150-HSPA [121/172] Oncell g3100 series system management settings

Moxa OnCell G3150-HSPA [121/172] Oncell g3100 series system management settings
OnCell G3100 Series System Management Settings
13-10
SMS Alert
To phone number 1 to 4: This is the phone number to which the automatic warnings message will be sent.
Encode format:
SMS Data Format
Text ASCII (7 bits) (default) 7 bits text format (160 bytes per packet)
Binary 8 bits binary (140 bytes per packet)
Unicode 16 bits Unicode (UCS2) format (70 bytes per packet)
Customized SMS
Customized SMS Settings: (default=Disable): Enable this function to allow customized SMS warnings and
events to be sent to the phone numbers configured in the SMS Alert section.
Remote Management
Remote SMS Control
Remote SMS Control can be used when your OnCell devices are installed in locations that are not easy to
access and where GPRS service is unstable. SMS service is one of the most reliable cellular services. Remote
SMS control provides: 1) the ability to report the current status of the OnCell device to your SMS sender; 2) the
ability to reboot the device so it can be recovered from any unexpected situation.