Aten CS261 [42/44] Operation modes

Aten CS261 [42/44] Operation modes
CS261 User Manual
32
Operation Modes
The below table describes the CS261’s two operation modes and their setting
options. Each setting’s active and inactive users’ statuses, as well as details on
switching users, are also included.
Note: 1. For more information on selecting a preset console, see DIP Switch
Settings Table, page 13.
2. The preset console can be activated and gain exclusive control by
pressing the Shift key six times within two seconds.
Operation
Mode
Setting Active User Inactive User Switching
Auto Mode Default First come, first
served
Using the key-
board or mouse
triggers a mes-
sage indicating
the system is in
use by the privi-
leged user.
Wait for privi-
leged user inac-
tivity (default
timeout: 5s).
Private Mode First come, first
served unless
preset console*
activated**
Computer can-
not be viewed
and heard.
Preset console
can gain exclu-
sive control by
pressing the Shift
key six times
within two sec-
onds. Doing so
again returns the
installation to
Default Auto
Mode.
Manual
Mode
C1 (Console 1)
Mode
Console 1 has
exclusive access
to the
computer***
Using Console
2’s keyboard or
mouse triggers a
message indicat-
ing the system is
in use by Con-
sole 1.
Press Scroll Lock
twice to switch to
C2 Mode.
C2 (Console 2)
Mode
Console 2 has
exclusive access
to the
computer***
Using Console
1’s keyboard or
mouse triggers a
message indicat-
ing the system is
in use by Con-
sole 2.
Press Scroll Lock
twice to switch to
C1 Mode.

Содержание